DEK 265gsx vision calibration

Electronics Forum | Sat Mar 27 23:44:16 EDT 2010 | dekhead

You were doing it right... for a 288. 3rd or 4th time in the last year or so I've had somebody do that. Glad I could help. http://www.dekhead.com

DEK 265gsx vision calibration

Electronics Forum | Thu Apr 01 23:53:26 EDT 2010 | dekhead

Sounds like SPC data collection is turned on with post print alignment inspection. Needs to be changed to "NONE" http://www.dekhead.com

DEK 265gsx vision calibration

Electronics Forum | Sat Apr 03 14:17:26 EDT 2010 | dman97

Thanks again for your help. I never would have guessed to check the SPC data settings because we never use it. Thanks so much!

DEK 265gsx vision calibration

Electronics Forum | Thu Apr 01 18:13:19 EDT 2010 | dman97

Since my last post, I have successfully calibrated my printer. Now I have noticed that after a print, the machine decides to check for fiducials again. A post print fiducial check. Do you know how to disable this? It is slowing down my process co

DEK 265gsx vision calibration

Electronics Forum | Fri Mar 26 23:07:07 EDT 2010 | dekhead

Just a guess: Are you printing your fiducials on the fiducial side of the board? Fidicial Side is for Vision Calibration, Bare Copper Side is for Offset Calibration (Step 5 of procedure says "copper side uppermost"). After printing 25 fiducials o

DEK 265gsx vision calibration

Electronics Forum | Fri Mar 26 21:48:56 EDT 2010 | dman97

Can someone explain to me what I'm supposed to do after I have done the vision offset calibration procedure? The manual tells me to put solder paste down on all 25 holes of the stencil. After this the board drops down and the machine scans each fidu

Dek 265

Electronics Forum | Sat Sep 22 13:02:40 EDT 2012 | elefu

Dek265 Upward vision is dim. Replaced bulb. Vision is still to dark to see anything. Bottom you can see fine. Any ideas?

DEK 265

Electronics Forum | Wed Dec 07 14:20:29 EST 2005 | Robert

I had a DEK 265LT with error code: motor comms failure.card 1, Axis123 fatal error-reinitialize machine during machine boost up I replaced new card 1 and still get the same error. Any suggestion would be greatly appreciated Thanks in advance, Rober

Dek 265

Electronics Forum | Mon Feb 02 11:51:54 EST 2004 | jsk

error code: motor comms failure.card3, Axis123 fatal error-reinitialize machine I swapped x3 and x4, and still get the same error. Any suggestion would be greatly appreciated Thanks in advance, jsk

DEK 265

Electronics Forum | Wed Dec 07 22:39:03 EST 2005 | Alan

Robert, you will have to re-load the MINT software. It only takes a couple of minutes to do this. This will fix out the errors. Refer to your DEK manuals on how to carry out this function. Cheers, Alan.


dek 265 vision error searches for Companies, Equipment, Machines, Suppliers & Information

ISVI - Industrial Sensor Vision International Corporation
ISVI - Industrial Sensor Vision International Corporation

Industrial Sensor Vision International specializes in advanced camera technology of high resolution fast speed cameras for automation, AOI, 2-D/3-D, SPI inspection and wafer inspection.

Manufacturer

3 Morse Road 2A
Oxford, CT USA

Phone: +1 203 592 8723

Baja Bid Auction JUL 9-10, 2024

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
One stop service for all SMT and PCB needs

Easily dispense fine pitch components with ±25µm positioning accuracy.
High Throughput Reflow Oven

High Throughput Reflow Oven
convection smt reflow ovens

World's Best Reflow Oven Customizable for Unique Applications
Fully Automatic BGA Rework Station

SMT & PCB Equipment - MPM, DEK, Heller, Europlacer and more...