Full Site - : dek actuators error (Page 21 of 46)

DEK265GSX >>>motor commumincation error

Electronics Forum | Thu Sep 25 09:56:23 EDT 2008 | mysmt

Hello, we are using DEK265gsx printers, at the minute ARCOM unit is not communicating with motor control cards 0,1,2,3 in Y1 enclosure. Checked CPU & RS232/485 cards from other DEK265, found okay. Any help will be appreciated. Mysmt

DEK 265 boot error

Electronics Forum | Thu Oct 26 12:14:34 EDT 2017 | lefwan

Our DEK 265 machine is showing this error message during starting…than it keeps re-starting in endless loops: Diskette drive failure on drive A Fixed Disk Controller Failure Fast ready check - Version 1.0 Copyright Arcom Control Systems Ltd. CMOS

DEK265GSX >>>motor commumincation error

Electronics Forum | Fri Sep 26 07:43:55 EDT 2008 | mysmt

Hello aj, 5V & 12 V checked & present.

DEK 265 boot error

Electronics Forum | Thu Oct 26 15:44:28 EDT 2017 | dekhead

Sounds like you need to go into set-up and define HDD. Does not auto-detect.

DEK 265 boot error

Electronics Forum | Fri Oct 27 10:43:08 EDT 2017 | sumote

i believe someone has left a floppy disk in the drive. eject it and reboot.

DEK 265 boot error

Electronics Forum | Fri Oct 27 12:00:44 EDT 2017 | dekhead

That would give "ABORT, RETRY, FAIL" message.

DEK 265 boot error

Electronics Forum | Fri Oct 27 15:22:29 EDT 2017 | sumote

I defer to your superior knowledge John.

DEK 248 squeegee error

Electronics Forum | Thu Feb 14 10:23:32 EST 2013 | vincent_qms

Hello, we have a DEK 248 just acted up with the squeegee orror. unit powered up initiated and when throght setup a job fine but when we started printing, the back squeegee came down, touched the stencil, stay for about 5 second then came back up with

DEK 248 squeegee error

Electronics Forum | Thu Feb 14 23:08:41 EST 2013 | dekhead

Squeegee error on a 248 is strictly that sensor (reed SW) on corresponding (Front / rear) squeegee cylinder is not seeing a change in state... Either a physical obstruction preventing cylinder from exending fully - OR- if it is extending fully, then

Data file open error

Electronics Forum | Wed May 16 00:14:45 EDT 2018 | leeg

We have a Dek Horizon and we have started getting a data file open error when trying to save files. This is resulting in us having to re-teach board fiducials etc in every time we switch back to a previous job. Any ideas?