Dek 248 Table out error

Electronics Forum | Wed Jun 19 18:44:56 EDT 2019 | dekhead

Is the signal making it to the SOL? Is it toggling when signal is present? RS Cylinder is to the rear of the RS rails.

Dek265 GSX Vision hardware error

Electronics Forum | Sun Nov 24 15:01:09 EST 2019 | dekhead

dekhead@att.net

Dek265 GSX Vision hardware error

Electronics Forum | Sat Nov 23 06:05:31 EST 2019 | hemantpang23

Hello Everybody, I have a problem with a DEK 265GSX, I get this error message: Vision hardware error Controlled lighting not responding FATAL ERROR - REINITIALISE MACHINE I have found that this might be due to a broken wire and I have checked all

Dek 248 Table out error

Electronics Forum | Wed Jun 12 09:37:13 EDT 2019 | key

We have a Dek 248 that when the table goes in it will not come out. We tested up/down sensors they are fine. The in and out sensors work in diagnostic. when we try to abort the unit the table should come out but doesn't. Any help would be great and a

DEK265 GSX chase clamp error

Electronics Forum | Mon Jun 04 09:59:03 EDT 2018 | bukas

correct, I also tried swapping motherboard but still same result. i the mean time i found battery leakage on Eurosys X1, replaced battery but now it won't start communication on machine initialization. got to repair it or something...

DEK265 GSX chase clamp error

Electronics Forum | Mon Jun 04 10:16:29 EDT 2018 | dekhead

I have seen battery leakage damage traces on MINT cards... Since you indicate failure on machine initialization, assume you are able to communicate / accomplish MINT download. (?)

DEK265 GSX chase clamp error

Electronics Forum | Tue Jun 05 07:30:13 EDT 2018 | bukas

sadly no, I can't open cmd since system doesn't come up, segment display on card shows .L and 8 blinking

DEK265 GSX chase clamp error

Electronics Forum | Mon Jul 16 09:15:57 EDT 2018 | bukas

problem was solved by cleaning lid bolt connector on chassis... both lid bolt and chase clamps are controlled by SCB34 card, it seams that there is an issue with poor connection on lid bolt triggering this bug. I assume its bug because other card beh

Dek 248 Table out error

Electronics Forum | Thu Jun 27 10:51:59 EDT 2019 | key

Good news we fixed the unit. The air pressure for the RS was not off. made a small adjustment for the in and the out. unit working fine.

Dek 248 Table out error

Electronics Forum | Thu Jul 18 13:15:25 EDT 2019 | dekhead

I guess you were able to locate the RS cylinder. Assuming adjustments to RS flow controls was your resolution.