Electronics Forum | Sat Nov 09 19:18:08 EST 2019 | kylehunter
Hi, I just set one of these up a month or so > ago, so it's all pretty fresh. The 265s have a > pressure sensor amplifier box that needs > calibration using the OEM calibration jig. OR you > can use a 3 quid digital luggage scale from Ebay. >
Electronics Forum | Sat Nov 09 20:08:34 EST 2019 | kylehunter
> Yeah, sorry, just noticed that bit on the > photo. I'll have to have a look at my machine on > Monday to see if there's anything that might > explain it. The pressure system is pretty much > the same on all the 265 variants so if
Electronics Forum | Wed Nov 06 06:34:26 EST 2019 | kylehunter
We have a DEK HORIZON 265 that seems to be having an issue with the pressure setting for the squeeges. It seems to have an override making the set point of the squeege pressure always be 5kg. I have it set to 12kg, but on the first print, it errors
Electronics Forum | Sat Nov 09 21:57:00 EST 2019 | dekhead
Not to be disagreeable, but sounds like "RichC" is describing earlier series 265 calibrations... (based upon location of PSR Amp and magnets to bypass cover interlock a 265MK1 (v. 1992-94). That "readings" calibration on your mach
Electronics Forum | Thu Nov 07 16:02:06 EST 2019 | kylehunter
OK, got a lot of information today doing some testing.. Version number:- 07 SP11 (985 B02) Released Dec 8 2006 I did the tool(less) calibration of the squeegee height, which worked fine, no error. Did a test print, as you can see from the image, t
Electronics Forum | Wed Aug 26 18:36:17 EDT 2020 | serge_pirog
Hello. Could I ask you for help. We have DEK Europa. We have changed ProFlow to squeegee head with feedback. After this during solder paste printing system shows the difference between set pressure (9 kg) and real pressure (7,5kg). I have read manual
Electronics Forum | Fri Feb 02 12:57:41 EST 2024 | spoiltforchoice
Arguably there is essentially one model the SP700 or 710. If you don't need 29" there is also the discontinued 210. However I don't think the brand matters all that much. You want what you can find at the right price and you need the options o
Electronics Forum | Sat Nov 09 19:37:52 EST 2019 | kylehunter
> the issue is the calibration. What you set it for > has to match what it actually reads or you get > the error screen at the end of every pass. If > you go into the maintenance menu ( using the key > next to the system button )