Full Site - : dek horizon vision error (Page 12 of 20)

Dek 265 GSX Error message

Electronics Forum | Mon Sep 19 11:29:33 EDT 2011 | padawanlinuxero

Hello guys ! I have a problem with a DEK 265 GSX, sometimes after download the vision or during, I get this error message: Vision hardware error Controlled lighting not responding FATAL ERROR - REINITIALISE MACHINE Now for a few weeks it gave me

DEK 265GSX Vision Error 1

Electronics Forum | Sun May 02 17:58:21 EDT 2010 | bruceb

When my DEK 265GSX boots I get a vision error1 and am asked to reinitialize. I cannot get into mainenance mode to troubleshoot. DEK told me over the phone that I have a bad Cognex card and it would be $20k to repair. This is crazy, has anyone seen th

DEK 265 Horizon Servo Following Error

Electronics Forum | Thu Jan 04 11:07:59 EST 2018 | ilavu

Ray, Did you solve this problem? I am having same error on same model machine. My problem is, when camera axis moves to look at the first fiducial, camera hits to the cleaner and error comes up with rising table error, camera axis not home. Even log

DEK PRINTER 265

Electronics Forum | Thu Dec 13 05:30:29 EST 2012 | sunyb123

i have facing a problem in dek 265 horizon that rising table position error ,please help in for solving this problem

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Thu Aug 27 09:29:04 EDT 2020 | serge_pirog

Yes, I calibrated the height, no error. How can I check that pressure was compensated? If we press button "continue" after some cycles of printing system will show "error".

DEK Horizon 02i Vision init issue

Electronics Forum | Fri Feb 09 14:49:04 EST 2024 | erikfriesen

Its looking like this was a CPU speed issue. The BIOS defaults to X3, and it needs X7.5 for the PCA-6180E CPU card.

DEK HORIZON 265 Squeege Pressure question

Electronics Forum | Thu Aug 27 03:19:21 EDT 2020 | dekhead

Have you done Squeegee Heights calibration? (no tools required) Does it complete cal routine without error? Does pressure compensate on next print, with corresponding squeegee, following acknowledgement of pressure error? The readings calibration, ge

Dek-265

Electronics Forum | Tue Sep 11 09:08:17 EDT 2007 | gemengr

Can not boot up . during down load vision system,an error come up VISION HARDWARE ERROR FAIL IN FUNCTION 1 STATE 2,VP STATE 0X28 ERR 0 any one know what's wrong with it.. thank you.

DEK Horizon 265

Electronics Forum | Sun Dec 23 00:11:43 EST 2007 | ktroym

When I try to bootup the machine I am getting an error that reads Dumping physical memory and a bunch of numbers & letters on the screen. The machine runs windows NT. Has anyone else had a problem like this before.

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 03:32:46 EST 2018 | raymccomb

yes we resolved the engineer did not set the servo to zero so it did not know its datum start point.


dek horizon vision error searches for Companies, Equipment, Machines, Suppliers & Information

ISVI - Industrial Sensor Vision International Corporation
ISVI - Industrial Sensor Vision International Corporation

Industrial Sensor Vision International specializes in advanced camera technology of high resolution fast speed cameras for automation, AOI, 2-D/3-D, SPI inspection and wafer inspection.

Manufacturer

3 Morse Road 2A
Oxford, CT USA

Phone: +1 203 592 8723