Electronics Forum | Mon Sep 03 04:05:56 EDT 2012 | omur
The issue has finally been resolved. It turns out that while checking the vision board, our engineers accidentally changed the address of the Analogue Board (which is adjacent to the vision board) - thus, leading to this startup error - with the unh
Electronics Forum | Fri Feb 29 16:42:34 EST 2008 | vikkaraja
Hello again, Has anyone experience any problem with their vision system on the DEK machine. Machine had been running fine for at least one year without any major problem until this week. Machine's response is very slow especially the vision system. M
Electronics Forum | Mon May 03 08:09:04 EDT 2010 | Jeff
Power up your machine and look at the vision card. If it has a red light then there is a problem with it. 20k is way to much to spend to fix this. I've sent out two cards for repairs in the past and got them fixed for $2200 each. If you want more inf
Electronics Forum | Wed May 05 04:25:42 EDT 2010 | vms
We sale the cognex cards for 3500.00 all of the time, think we need to raise our prices. Right bruce? Harry
Electronics Forum | Fri Feb 09 13:51:02 EST 2024 | erikfriesen
I've looked at the logs, its error 234. Looking backwards, I see where this has happened some time ago as well.
Electronics Forum | Fri Sep 14 10:30:45 EDT 2012 | dekhead
I believe there was a software issue as well; Initially installed software (4.03) replacing existing 2.12. After that it got past the "Stack Overflow" and displayed the expected error for incorrect addressing on PCAD12... BTW solution to "vision boa
Electronics Forum | Wed May 18 18:36:22 EDT 2005 | global
Ok here's one for ya. We have a DEK 260 with a Cyberbectic vision system, 1 of about only 50 made as told to me by a DEK service Tech. So if anyone has operated one of the other 49 you may be able to help. The Service techs at DEK are not familiar en
Electronics Forum | Tue May 04 11:30:19 EDT 2010 | tsventek
I just had the same issue, it was a corrupt fiducial file in the program that kept on loading when booted. If your vision card is working follow these steps: Reboot the machine, press F5 when the computer beeps to enter DOS, delete the file maninf.d
Electronics Forum | Fri Oct 26 11:29:41 EDT 2001 | kaopsahl
I have two DEK 288s set up in our shop, we used to use a Fuji GSP_III. I could not possibly say enough good things about the DEKs - they are incredible. The only real complaint I have with them is that if an error pops up that locks up the software -
Industrial Sensor Vision International specializes in advanced camera technology of high resolution fast speed cameras for automation, AOI, 2-D/3-D, SPI inspection and wafer inspection.
3 Morse Road 2A
Oxford, CT USA
Phone: +1 203 592 8723