Electronics Forum | Sun Nov 24 15:01:09 EST 2019 | dekhead
dekhead@att.net
Electronics Forum | Mon Jun 04 09:59:03 EDT 2018 | bukas
correct, I also tried swapping motherboard but still same result. i the mean time i found battery leakage on Eurosys X1, replaced battery but now it won't start communication on machine initialization. got to repair it or something...
Electronics Forum | Mon Jun 04 10:16:29 EDT 2018 | dekhead
I have seen battery leakage damage traces on MINT cards... Since you indicate failure on machine initialization, assume you are able to communicate / accomplish MINT download. (?)
Electronics Forum | Tue Jun 05 07:30:13 EDT 2018 | bukas
sadly no, I can't open cmd since system doesn't come up, segment display on card shows .L and 8 blinking
Electronics Forum | Mon Jul 16 09:15:57 EDT 2018 | bukas
problem was solved by cleaning lid bolt connector on chassis... both lid bolt and chase clamps are controlled by SCB34 card, it seams that there is an issue with poor connection on lid bolt triggering this bug. I assume its bug because other card beh
Electronics Forum | Fri Dec 20 05:44:43 EST 2019 | hemantpang23
Thanks for your reply We checked all the hardware found ok voltages are as per specifications Suspecting software issue but don't have software for installation Please confirm if you have this software version 04.03 so that we can have last try
Electronics Forum | Tue May 29 08:37:52 EDT 2018 | bukas
screen alignment chase clamp state is ON, it can be turned OFF but when I get out of diagnostics machine turns them ON again. Tooling is set to magnetic, and on other machines I have chase clamps are not energized all until board is in machine and st
Electronics Forum | Thu Jan 19 07:50:19 EST 2006 | Walter
HI bobplan.... ! I'm brazilian an i have a error message too ! But the message is "System Error... Please Check the system" And the machine freeze ! Please .. help me !
Electronics Forum | Wed Aug 12 17:41:15 EDT 2015 | edwaterfall01
Sorry for all the typos in the last message. As the machine was powered OFF for two weeks I would have expected a battery problem. Can you capture a Logicimm file and see what the file says before the heart beat messages?
Electronics Forum | Thu Apr 28 05:52:21 EDT 2022 | sophyluo1985
Please send the error message to my email quinnsmt@gmail.com