Electronics Forum | Fri Jun 09 21:33:30 EDT 2006 | Professor Besserwisser Dr Dr PhD
I think You should try to do the Delta X test, because there is a mine somewhere in the universe that has the bahodium who take care of all of this. Hahahaha I couldn't resist.
Electronics Forum | Mon Jun 09 16:58:47 EDT 2008 | adamcrum
Does anybody using Vitronic Soltec's Delta 5 wave have any problems with their Select X. Apparently there are others out there (according to our rep) who are having problems. I am curious as to what they are and what you are doing to fix it.
Electronics Forum | Fri Jun 09 21:53:07 EDT 2006 | Professor Besserwisser Dr Dr PhD
I am sorry, but I hope No hard feelings? :) As for an answer to Your question: No I can not see the reason for using three heat zones on the wave. Anybody else?
Electronics Forum | Mon Jun 12 10:34:06 EDT 2006 | cuculi54986@yahoo.com
My brother-in-law is a DDS and I trust him. We had some problems with solder voids in the past, and he was invaluable. He'd drill them out and fill them with SAC3240X+.
Electronics Forum | Mon Jun 12 10:46:38 EDT 2006 | Chunks
It's hard to believe MoonMan spends this much time typing these rants. Guess the boys at ever so much higher I.Q. standard of engineering, IPC, kicked him out there too.
Electronics Forum | Tue Jun 13 08:49:34 EDT 2006 | russ
Your new problem is inadequate flux coverage. This may be a contributer as well to the BNC issue. Russ
Electronics Forum | Mon Jun 29 07:17:25 EDT 2015 | donlockard
Seho maxi wave 3240 should be considered as well. Invented full tunnel nitrogen systems that have lower operating costs and provide yields unlike what can be achieved by air wave systems.
Electronics Forum | Wed Jul 29 12:52:15 EDT 2015 | e405453
Hi Thank you for the reply. I will going on contacting my supplier. we are currently using 2 different wave machines a Soltec Delta wave & Opti Flux on SpeedLine Machine. Th
Electronics Forum | Mon Apr 09 11:31:36 EDT 2018 | emeto
I would still focus on the sensors first. Experiment and see if they are really registering correctly. Still might be a sensor malfunction, timing issue(enough time to register)or some actual debree on it that prevents it from changing state properly
Electronics Forum | Mon Apr 09 13:50:38 EDT 2018 | justconmac
Thank you, yes I am definitely going to go back through and clean them thoroughly and monitor them, especially at rack location.