Electronics Forum | Fri Nov 03 11:30:29 EDT 2017 | davef
regarding dwl comment, "For low volume hand assembly, deionized water or IPA should work fine." Deionized water: Deionized water is corrosive. It needs to be removed. Proof? Drop a copper coin into a covered jar of DI water and watch what happens ov
Electronics Forum | Thu Nov 02 15:45:04 EDT 2017 | dleeper
For low volume hand assembly, deionized water or IPA should work fine.
Industry News | 2022-10-13 07:44:15.0
I.C.T SMT Vacuum Reflow Oven Machine helps you to solve the problem of High Solder Voids Rates
Industry News | 2013-01-15 13:14:32.0
Aqueous Technologies will exhibit in booth #3127 at the upcoming IPC APEX EXPO, scheduled to take place February 19-21, 2013 at the San Diego Convention Center in California.
Technical Library | 2019-11-17 22:46:45.0
Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers
Technical Library | 2013-04-18 16:46:42.0
Conformal coatings are considered a method of providing corrosion protection to electrical assemblies used in high-humidity or harsh environments. They are applied to PCBs for various reasons: to protect from moisture and contamination, to minimize dendritic growth, to provide stress relief, and for insulation resistance. These contribute to more durable handling, enhanced device reliability, and reduced warranty costs. Increased miniaturization of new circuit board designs requires flexible, low stress coating material to protect delicate components and fine-pitch leads. Silicone conformal coatings offer many advantages that address the general trend of ongoing PCBs designs, such as: high flexibility and low modulus to reduce stress on delicate or small components... First published in the 2012 IPC APEX EXPO technical conference proceedings.
http://www.gpd-global.com No drip no drool across a wide range of fluid viscosities (low-to-mid and low-to-high). No manual adjustment to compensate for pump variability. Truly Volumetric PCD Pumps for total control of dispensing fluids. Ability to
· What is the difference between SMT vacuum reflow soldering machine and ordinary reflow soldering machine? · What problems can be solved by smt vacuum reflow soldering machine? · What is the basic principle of vacuum reflow machine? · Ho
Career Center | Phoenix, Arizona | Engineering,Management,Production,Quality Control,Research and Development,Sales/Marketing,Technical Support
• Highly motivated, solution oriented professional with proven record synergizing scientific, engineering, and business administration backgrounds to drive and sustain customer satisfaction and long term improvements. • Articulate communicator that a
SMTnet Express April 18, 2013, Subscribers: 26335, Members: Companies: 13359, Users: 34594 Effect of Silicone Conformal Coating on Surface Insulation Resistance (SIR) For Printed Circuit Board Assemblies by: Carlos Montemayor; Dow Corning
Article Return to Front Page A Low Temperature Alte
Surface Mount Technology Association (SMTA) | https://www.smta.org/news/smta_calendar/calendar.cfm
Europe Monday, 6th July @ 2:30pm - 4:00pm GMT (9:30am - 11:00am US Eastern Time) Presenter: Bob Willis, SMTA Europe Overview The webinar provides an introduction and a better understanding of the soldering process and the effect of poor solderability on
Heller Industries Inc. | https://hellerindustries.com/wp-content/uploads/2018/07/last-will-of-bga-void.pdf
: IPC Solder Products Value Council (SPVC), “The Effect of Voiding in Solder Interconnections Formed from Lead-free Solder Pastes with Alloys of Tin, Silver and Copper” [6