Full Site - : elmo (Page 5 of 5)

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:33:32 EDT 2014 | cflames17

It could very well be the Safety Relay located inside the ELMO PSU (Bottom left in computer cabinet). I just had the same problems on 2 MY9's within 2 months apart. the Part cost around $700.00 from Mydata (Now Mycronic). These fail commonly with old

Mydata board K-029-0016 Elmo Power

Electronics Forum | Wed Sep 19 10:34:44 EDT 2018 | sarason

Now I have to guess and make a few assumptions. Without looking at the back side of the board my guess is you have some 400-100V diode bridges before the resistor ,zener and the FET . The FET is a 500V 0.85 Rdson NFET. All of this suggests a chopper

Conformal Coating

Electronics Forum | Fri Dec 13 10:23:55 EST 2002 | davef

Bright ideas??? Bright ideas!!! I got bright ideas. In order of decreasing luminosity: * Stop installing the socket, solder the PLCC to the board, dip the board. The socket is a waste of time and money. You never replace the PLCC in the field, a

Coating under Mil connector....

Electronics Forum | Thu Dec 22 21:29:05 EST 2005 | davef

Josh: Room Temperature Vulcanizing (RTV) is Dow Corning's trade name for it's family of silicone cure sealants. RTV is about the worst kind of coating there is. Its chemistry is highly ionic and it requires atmospheric humidity absorbed to "complete

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 03:33:42 EST 2014 | hans88

hello people, we have a my12 wich has a problem it gives the following error during hardware initialization: F-MOT-MSETDYN Y/1236 :Motor amplifier channel a error. after this error it says hardware initialization failed. this prevents us of using

Sm t t t t t net
Previous 1 2 3 4 5  

elmo searches for Companies, Equipment, Machines, Suppliers & Information