Electronics Forum | Mon Apr 06 14:02:05 EDT 2020 | tomdegas
I have tried that Tim and I get the same error message. Originally it would pass in the service menu but when I switched back to TPsys, it would fail. I tested the friction one time it did pass and it was well withing the range. Thanks for the res
Electronics Forum | Thu Dec 28 20:46:49 EST 2023 | padawanlinuxero
I was use to work with the machine but it has being several years since I had one in my hands, but i got the same error message, I kinda remember there are some sensors in the top part of the hydra try to see if theres dirt or something not letting t
Electronics Forum | Sat Feb 22 09:41:44 EST 2020 | tomdegas
I am getting a F-MOT-MSEDYN HYDRA Z/156 error when I try to initialize Hardware on my My9. Interestingly though when I go into the "Service" program, I can initialize the Hydra Z with no problem. But when I try in TPSys, it doesn't pass and I get t
Electronics Forum | Fri Feb 21 10:50:00 EST 2020 | tomdegas
I am getting the following error on our MY9 during hardware initialization: F-MOT-MSEDYN HYDRA Z/156 Motor Timeout After the Theta test, The HYDRA head moves slowly all the way to the bottom and then moves slowly back up and the system fails initia
Electronics Forum | Thu Mar 05 07:40:55 EST 2020 | tomdegas
I swapped the mi boards with ones from a working My12 machine and the same results. To recap my problem: On "Hardware Initialization" the center jaws open and close, the Hydra Theta belt moves back and forth, the Hydra head moves all the way down an
Electronics Forum | Fri Feb 21 17:12:43 EST 2020 | SMTA-Alex
Have you performed the maintenance? It might need grease, or there might be excess old grease, that's putting more friction on the Hydra Z. Check if there might be interference from the vacuum tubes or wires.
Electronics Forum | Fri Feb 21 18:27:23 EST 2020 | tomdegas
Thanks for the quick response. I’ll try it tomorrow and let you know if that worked. I do grease it but there may be residual older grease still there.
Electronics Forum | Tue Mar 03 13:35:29 EST 2020 | emeto
So to sum up: you have no mechanical blockage, you have new motor and encoder. That leaves only two more parts(cable and Hydra Z-Controller).
Electronics Forum | Tue Mar 03 13:40:44 EST 2020 | tomdegas
I swapped out the cable with no luck. The Hydra Z controller is the board on the right side of the Hydra head with everything plugged into it right?
Electronics Forum | Tue Mar 03 14:38:55 EST 2020 | emeto
I don't remember as it has been a while, but this is the board you have to replace.
COT specializes in high quality SMT nozzles and consumables for pick and place machines. We provide special engineering design service of custom nozzles for those unique and odd components.
2481 Hilton Drive
Gainesville, GA USA
Phone: (770) 538-0411