Electronics Forum | Tue Mar 03 14:38:55 EST 2020 | emeto
I don't remember as it has been a while, but this is the board you have to replace.
Electronics Forum | Wed Mar 04 14:32:21 EST 2020 | bk
The mot mi board is the first board but it is two boards tied together so you need to undo the screws on the first 2 boards on the left.
Electronics Forum | Sun Dec 17 13:52:59 EST 2023 | tomdegas
How can I bypass the " Hydra force sensor can't calibrate" during the "Hardware Initialization" test. This is stopping me from starting the machine.
Electronics Forum | Wed Mar 04 12:51:41 EST 2020 | bk
That error means your hydra z did not reach it's specified position. With the machine on you should be able to manually push the hydra down and let it come back up. Make sure it isn't being held up or hitting anything as goes down. Lots of times a pa
Electronics Forum | Fri Mar 06 14:33:53 EST 2020 | bk
Another thing you can check is where the bar comes down off of the hydra z motor there is a little bearing you can see from the front make sure that bearing is turning even oil it up a little. You can also adjust the tension by loosening the tiny set
Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex
The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo
Electronics Forum | Mon Apr 06 17:08:30 EDT 2020 | tima
Try swapping XWB board that is on top of X-Wagon. Have you try that? All signals go thru there. Another thing can be those 2 ribbon cables that are behind of X-Wagon. How long ago did you change them? What I would do is to move X to different positio
Electronics Forum | Wed Mar 04 13:45:01 EST 2020 | tomdegas
I appreciate the help. The Hydra travel is fine and goes down and back up with no trouble. I swapped the Z Mot board with the Y Mot board with no change. The long ribbon cables were changed about a month ago but I will inspect them again to be sure.
Electronics Forum | Thu Jun 28 14:45:55 EDT 2018 | aksaustin
What error is it throwing?
Electronics Forum | Mon Jun 12 10:38:00 EDT 2017 | highmillr
Getting this error more frequently. Whats causing this?? I have to reset machine every time costing man hours. After resetting its fine but does it at least once a day.