MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Tue Mar 03 14:38:55 EST 2020 | emeto

I don't remember as it has been a while, but this is the board you have to replace.

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 14:32:21 EST 2020 | bk

The mot mi board is the first board but it is two boards tied together so you need to undo the screws on the first 2 boards on the left.

Force sensor error on MyData My12

Electronics Forum | Sun Dec 17 13:52:59 EST 2023 | tomdegas

How can I bypass the " Hydra force sensor can't calibrate" during the "Hardware Initialization" test. This is stopping me from starting the machine.

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 12:51:41 EST 2020 | bk

That error means your hydra z did not reach it's specified position. With the machine on you should be able to manually push the hydra down and let it come back up. Make sure it isn't being held up or hitting anything as goes down. Lots of times a pa

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 14:33:53 EST 2020 | bk

Another thing you can check is where the bar comes down off of the hydra z motor there is a little bearing you can see from the front make sure that bearing is turning even oil it up a little. You can also adjust the tension by loosening the tiny set

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex

The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Mon Apr 06 17:08:30 EDT 2020 | tima

Try swapping XWB board that is on top of X-Wagon. Have you try that? All signals go thru there. Another thing can be those 2 ribbon cables that are behind of X-Wagon. How long ago did you change them? What I would do is to move X to different positio

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 13:45:01 EST 2020 | tomdegas

I appreciate the help. The Hydra travel is fine and goes down and back up with no trouble. I swapped the Z Mot board with the Y Mot board with no change. The long ribbon cables were changed about a month ago but I will inspect them again to be sure.

estop error wont go away on vitronics delta max

Electronics Forum | Thu Jun 28 14:45:55 EDT 2018 | aksaustin

What error is it throwing?

Camera not parked error on mpm ap 25.

Electronics Forum | Mon Jun 12 10:38:00 EDT 2017 | highmillr

Getting this error more frequently. Whats causing this?? I have to reset machine every time costing man hours. After resetting its fine but does it at least once a day.


error on my500 searches for Companies, Equipment, Machines, Suppliers & Information

Count On Tools, Inc.
Count On Tools, Inc.

COT specializes in high quality SMT nozzles and consumables for pick and place machines. We provide special engineering design service of custom nozzles for those unique and odd components.

Manufacturer

2481 Hilton Drive
Gainesville, GA USA

Phone: (770) 538-0411

consignment program

High Resolution Fast Speed Industrial Cameras.
High Throughput Reflow Oven

Easily dispense fine pitch components with ±25µm positioning accuracy.
Pillarhouse USA for Selective Soldering Needs

High Throughput Reflow Oven


SMT & PCB Equipment - MPM, DEK, Heller, Europlacer and more...