Industry Directory: esd control when humidity is (3)

StaticTek

Industry Directory | Consultant / Service Provider / Distributor

StaticTek provides static control equipment, supplies and services.

SMT Dry Cabinets by Eureka Dry Tech

Industry Directory | Consultant / Service Provider / Manufacturer

Eureka Dry Tech's IPC/JEDEC J-Std-033c Ultra Low Humidity Dry Cabinets provides moisture/humidity controlled storage of MSD,PCB, IC packages. Drying technology trusted by millions in replacing baking, nitrogen & desiccant packs.

New SMT Equipment: esd control when humidity is (8)

McDry Ultra-Low Humidity Storage Cabinets

McDry Ultra-Low Humidity Storage Cabinets

New Equipment | Board Handling - Storage

Prevent your components from micro-cracking during reflow with proper Ultra-Low Humidity Storage. DXU models of maintain1%RH Wide range of cabinets including UL/C models Conforms to IPC/JEDEC J-STD 033B.1 Dehumidifies ICs to prevent micro-crack

Seika Machinery, Inc.

Eureka SDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet

Eureka SDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet

New Equipment | Board Handling - Storage

SDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet Specs: Model: SDC-1001 Fast Super Dryer Capacity: 657 Liters Humidity Range: LESS THAN 10% Recovery Time: Recovers to ≤ 10% RH within 30 minutes after accessing door for 30 seconds or less. Ex

SMT Dry Cabinets by Eureka Dry Tech

Electronics Forum: esd control when humidity is (14)

Humidity control in assembly area.

Electronics Forum | Mon May 01 17:29:25 EDT 2000 | Joe

Hi, We have a climatic controlled assembly area, with a constant temp of 22 deg C and a relative humidity of 40 - 50 %. What I would like to ask is how should I approach a situation when the humidity starts to decrease to below 40%. The situation I'

Re: Humidity control in assembly area.

Electronics Forum | Wed May 03 20:04:21 EDT 2000 | Dave F

Joe: Hey, just hose everyone down with water when your humidity starts to decrease to below 40%. ;-) Actually, that�s how some humidity controllers work, when added to your heating system. Well basically that�s how they work. I�m not tryin� to

Industry News: esd control when humidity is (5)

Essemtec's Tower Increases Variosystems’ Flexibility of Production

Industry News | 2011-02-26 16:00:45.0

Essemtec AG announces that its Tower Automatic Storage System simplifies logistics and increases the flexibility of production for Variosystems, an international electronics manufacturing subcontractor

ESSEMTEC AG

Seika Machinery Offers Discount on McDry PCB Storage Cabinets to Help Customers Meet IPC Storage Guidelines

Industry News | 2012-06-25 12:38:27.0

Seika Machinery, Inc. announces a special sale to assist its customers with meeting the IPC 1601 PCB Storage and Handling Guideline

Seika Machinery, Inc.

Technical Library: esd control when humidity is (1)

Symor ESD storage dry cabinet(Working principle)

Technical Library | 2019-04-08 23:21:29.0

Climatest Symor® adopts molecular sieve to dry air, the whole system is controlled by microcomputer, when humidity is high, It will start to absorb moisture,when the humidity reach the pre-set value, it will stop absorbing, and then discharge the water to outside the cabinet by heating,again and again by automatic control. The most effective and environment-friendly moisture-absorbing desiccant is molecular sieve, molecular sieve is the microporous crystal material synthesized by silicon and aluminium oxide. In order to keep the crystal net discharge to be zero, atoms with cations are located in the crystal structure.and the cation used in these synthetic crystals is usually sodium. At present, there are two kinds of molecular sieves widely used in the dry box industry: Class A and Class X. Molecular sieves are synthesized, shaped and activated under strictly controlled production processes. The whole controlled sythesis process can ensure consistency of the three-dimensional pore size. 3A molecular sieve pore size is 3 angstroms, 4A molecular sieve pore size is 4 angstroms; 13X molecular sieve pore size is 8.5 angstroms. The working principle of molecular sieve: Molecular sieves adsorb molecules onto the crystal surface by physical attraction force. Since 95% surface area of the molecular sieve is within aperture,it needs to screen the adjacent molecules by different size. Only small size molecules can enter into the inner adsorption surface of the molecular sieve through the crystal aperture. This selective adsorption phenomenon is called molecular sieve effect. The molecular sieve adsorption capacity and charge density (polarity) are further related to the adsorbed molecules. The molecular sieves can further distinguish which of the mixed molecules can be adsorbed and determine to what extent the charge density can allow the molecules to be adsorbed onto the crystal. Water molecules are particularly small (2.6 angstroms), that belong to highly polar molecules (very strong positive and negative electron density), and are easily adsorbed by molecular sieves, even under very low moisture condition,once the water molecules are adsorbed,they will be firmly fixed on the crystal. The environment-friendly moisture absorption device is equipped with molecular sieve. When it’s absorbing, the memory alloy controller is in tensile state, and the spring is in contractive state,which just make the valve contact the outer baffle, this insulates the outside air from inside dry box air to achieve dehumidification purpose; and after molecular sieve absorbed moisture inside dry box and become saturated, the program will automatically control the memory alloy device to shrink it so that the valve reaches the inner baffle position. Meanwhile, due to the shrinkage of the memory alloy, the spring is stretched and the valve is pulled out of the outer baffle,so that the moisture in molecular sieve will be discharged into the outside. after the dehumidifying process finished, the program automatically control and reset the memory alloy and spring,to restart absorbing status.

Symor Instrument Equipment Co.,Ltd

Videos: esd control when humidity is (3)

Increase your capacity by 100% and use 20% less footprint with the ultra flexible and easy to integrate UltraFlex 3600

Increase your capacity by 100% and use 20% less footprint with the ultra flexible and easy to integrate UltraFlex 3600

Videos

Increase your capacity by 100% and use 20% less footprint with the ultra flexible and easy to integrate UltraFlex 3600. Owners of the new system will not have to compromise anymore on storage mix because of predefined configurations or expensive cust

Southwest Systems Technology

Ruichi Robot R351

Ruichi Robot R351

Videos

Ruichi Standard Soldering Robot R351. Soldering Tip can be designed according to your products.

Ruichi Robot(shenzhen) Co.,Ltd.

Events Calendar: esd control when humidity is (2)

Atlanta Chapter Technical Meeting: The Science of Humidity Control in Manufacturing

Events Calendar | Thu Jul 20 00:00:00 EDT 2023 - Thu Jul 20 00:00:00 EDT 2023 | Suwanee, Georgia USA

Atlanta Chapter Technical Meeting: The Science of Humidity Control in Manufacturing

Surface Mount Technology Association (SMTA)

Oregon Chapter Tutorial: How Clean is Clean and How Do You Know for Sure?

Events Calendar | Wed Apr 21 00:00:00 EDT 2021 - Wed Apr 21 00:00:00 EDT 2021 | ,

Oregon Chapter Tutorial: How Clean is Clean and How Do You Know for Sure?

Surface Mount Technology Association (SMTA)

Express Newsletter: esd control when humidity is (701)

SMTnet Express June 20 - 2013, Subscribers: 26136

SMTnet Express June 20, 2013, Subscribers: 26136, Members: Companies: 13402, Users: 34820 Implementation of Effective ESD Robust Designs by: Industry Council on ESD Target Levels While IC level ESD design and the necessary protection levels

Partner Websites: esd control when humidity is (538)

When to Use FR4 Printed Circuit Boards | Imagineering, Inc.

Imagineering, Inc. | https://www.pcbnet.com/blog/when-to-use-fr4-printed-circuit-boards/

consideration when it comes to materials, design and functionality. As one of the most common dielectric materials, FR4 is frequently used in a wide variety of PCBs

Imagineering, Inc.


esd control when humidity is searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next
2024 Eptac IPC Certification Training Schedule

Wave Soldering 101 Training Course
Win Source Online Electronic parts

Software for SMT placement & AOI - Free Download.
PCB Handling Machine with CE

Training online, at your facility, or at one of our worldwide training centers"
used smt parts china