Electronics Forum | Wed May 08 11:20:24 EDT 2013 | amelby
Thanks for the info on the Hydra tubes that will be helpful. I found the answer from one of the Mydata techs. The Camera needs the hydra head to go slower then 1.9m/sec and the setting was at 1.8m/sec. They found out that even if the machine was set
Electronics Forum | Tue May 28 12:56:22 EDT 2019 | dekhead
It is a communications failure between the CPU and the Cognex card. Does comms initiate between the 2 cards (flashing green on both)? or does it immediately come up red LED on Cognex? Have you reseated the CPU board as well as the Cognex? Is this a s
Electronics Forum | Mon Jul 30 17:32:34 EDT 2007 | chrisgriffin
When you teach the "teach boardstop Y" make sure the camera is seeing the leading edge of the board and not too close to the rails. It should calculate the pre-stop position correctly. I assume you have thoroughly checked the sensor. Also check th
Electronics Forum | Thu Jan 04 11:07:59 EST 2018 | ilavu
Ray, Did you solve this problem? I am having same error on same model machine. My problem is, when camera axis moves to look at the first fiducial, camera hits to the cleaner and error comes up with rising table error, camera axis not home. Even log
Electronics Forum | Thu Dec 08 01:17:35 EST 2011 | mk15
Hi, I look Pick & Mount and Mount action was NORMAL - OK. When the head pick component then stop outside lamp housing (fixed camera - recognition camera) and then discard component. It repeat 3x, and Error E2. When I do adjust assistant for componen
Electronics Forum | Tue May 27 04:52:25 EDT 2014 | hemant_pang23
Need help to resolve the problem in DEK265 paste printer The error messages are as per following details 1. When switch on the Machine we are getting error message like " Rising Table Error" -Position error. 2.While loading the Mint we are get
Electronics Forum | Fri May 02 16:23:06 EDT 2014 | jimmyboz
Bits 0-3, no, Bit 4, MFU2 with error parts conveyor for camera 12, Bit 5,MFU1 with error parts conveyor for camera 12. The other guy is also correct, where to discard a component is in the part data. Still checking, please reply quickly if you solve
Electronics Forum | Fri Aug 28 11:39:23 EDT 2015 | dlee87
I have an issue with this DEK printer our company > has been having for over a year now. It seems > that DEK can’t narrow down what the issue > actually is as well. The printer is a DEK Horizon > 03i 09 SP13 P02. We are having an issue with
Electronics Forum | Thu Jun 24 07:50:36 EDT 2021 | ouaret
we have a Cyberoptics Flex ultra HR machine (model N 8010949). the alignment of camera 1,3,5 and 2,4 is impossible because the images from each Fire wire adapter don't have the same size. we tried to calibrate with the target board, but also unsucce
Electronics Forum | Fri Jan 05 12:02:28 EST 2018 | ilavu
Camera works fine from home to ref. position to fiducial1 and 2. Problem shows up from home to board stop. AC voltage between AC1 and AC2 is 41.7 and during move it drops to 41.5.