Full Site - : f-mot msetdyn hydra z (Page 1 of 2)

mydata 19 error

Electronics Forum | Wed Feb 19 09:52:45 EST 2014 | brendansales

Dear Rob, Got to the maintenance menu, under the Motor section, I selected Z motor and tried to initiate motor, there was no movement on the machine and I had the error message as below: F-MOT-MSETDYN Z/12: Position counter dead I suspect that ser

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 16:11:12 EDT 2024 | kingkelvin

In calibration menu - I see coarse measurement of z unit offset, z-unit offset, measure hydra camera z level, coarse adjust hydra tool offsets, and measure hydra tool lengths 1 - 8 - would it be any of these that I should run?

MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Thu Oct 11 00:11:49 EDT 2018 | mk15

I am looking for some help for where to look to fix this MY15E problem. We started the machine after the weekend and this error code comes. F-MOT-MSETDYN z/3: Upper end point outside limit. Any suggestions? Thanks

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 14:28:26 EDT 2024 | kingkelvin

We have MY9 - when it changes hydra tooltips - most of the time it makes a small "hitting" type noise - with error F-MOT MOVESLOWMOVE HYDRA Z/205 - however you can just hit continue and it will always change the tools and finish the board - I've un-i

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 16:51:00 EDT 2024 | tey422

Since you only saying it's the hydra error, then only run the hydra calibrations. Sometime the calibration can end up causing more issue if not run it correctly. I would do the hydra camera Z level (1st). If it fixes the issue then you no need to do

Mydata MY12 Hydra Theta error

Electronics Forum | Tue Nov 15 23:03:07 EST 2011 | supse

Hi I have a problem with one of our MY12 machines, the machine stops very often (approx. 10-20 times a day) writing the following error message : f-mot-msetdyn hydra theta/205(f-hrdw-3). We then have to reinitialize the machine to continue productio

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 17:13:11 EDT 2024 | tey422

It's been long time, me memories are fading away. If I remember correctly, you would need small flat surface plate or something to cover up the "linescan" hydra camera, so from the reflections value then it can calculates the actual height "lowest"

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 18:00:31 EDT 2024 | alexv

The tapping noise is what you hear when Hydra taps each tool on the tool bank to make sure the tips are seated well. The error is a Z-motor problem. The gear is at the top of the Hydra and needs grease. Have you cleaned the old grease and applied new

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Feb 21 10:50:00 EST 2020 | tomdegas

I am getting the following error on our MY9 during hardware initialization: F-MOT-MSEDYN HYDRA Z/156 Motor Timeout After the Theta test, The HYDRA head moves slowly all the way to the bottom and then moves slowly back up and the system fails initia

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Thu Mar 28 15:18:21 EDT 2024 | tey422

From the error message, might have to do with the "Z"-axis. You didn't mention you redo the calibration or not, then you should run that too. My guess would be "Z reading maybe slightly off". BTW, last time I work with those Mydata machine were bac


f-mot msetdyn hydra z searches for Companies, Equipment, Machines, Suppliers & Information