MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:33:32 EDT 2014 | cflames17

It could very well be the Safety Relay located inside the ELMO PSU (Bottom left in computer cabinet). I just had the same problems on 2 MY9's within 2 months apart. the Part cost around $700.00 from Mydata (Now Mycronic). These fail commonly with old

F-MOT-MSETDYN Theta/12: No axis movement detected by transducer

Electronics Forum | Fri Feb 07 13:17:32 EST 2020 | bk

I am assuming you are initializing each motor individually through the service program. The z motor theta is hard to see so I put a mark on it with a colored marker so you can watch if the midas tool nozzle is actually turning or not. You should be a

F-MOT-MSETDYN Theta/12: No axis movement detected by transducer

Electronics Forum | Fri Feb 14 16:01:28 EST 2020 | bk

On the my12 the panel on the front of the machine comes off two screws each corner to loosen the panel. There is a pull out tray that gives you easier access to the computer, ps3, etc. It will be the box in the center on top it should label where eac

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 09:40:14 EDT 2014 | rgduval

I'm surprised MyData is pushing the service call. They're usually pretty good at walking you through some troubleshooting steps before going straight to the service call. So, the failure sounds like an encoder failure; the encoders are attached to

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 03:33:42 EST 2014 | hans88

hello people, we have a my12 wich has a problem it gives the following error during hardware initialization: F-MOT-MSETDYN Y/1236 :Motor amplifier channel a error. after this error it says hardware initialization failed. this prevents us of using