Full Site - : f-mot1 (Page 1 of 2)

Mydata L-19-029-2F

Mydata L-19-029-2F

Parts & Supplies | Pick and Place/Feeders

MOT-1 ED-2F Rev. 0 OK: MA Date: 1996.04.14

SMTVYS

Mydata L-19-029-2F

Mydata L-19-029-2F

Parts & Supplies | Pick and Place/Feeders

MOT-1 ED-2F Rev. 0 OK: MA Date: 1996.04.14

SMTVYS

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Sun Oct 24 08:07:06 EDT 2021 | artem

Hello, I have a Mydata TP11-UFP which stopped working. It prints F-MOT1-38/245:MSETDYNX during initialisation. Any idea what could be wrong? I have already replaced the capacitors and the Inrush Current Limiters on the "L-19-588-18" board. Also ins

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 12:30:30 EDT 2013 | shankar2013

We are having a problem with our Mydata TP9-2U where the machine shuts down during a job with this message seen on the service monitor -- F-MOT1-26/156:MOVFI: MOTOR TIMEOUT Has anybody seen this problem?

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Tue Oct 26 15:47:37 EDT 2021 | harry

I just got the same machine with very low hours. What has been your experience? This is my first mydata machine.

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Fri Oct 29 17:48:46 EDT 2021 | artem

Hello, I have found the problem. The capacitors on the PAIB board were leaking. They have even demaged some traces and vias on the PCB and the -5V supply on the PAIB board was not working anymore. Got it working again :)

TP18-UFP initian failure

Electronics Forum | Tue Jan 16 10:45:36 EST 2007 | PaulD

Im looking for some help I have a tp18 that will not initiate the error is f-mot1-38-245:msetdynx I tried several things. I've swapped mot cards to not avail, checked the long ribbon cable and so forth if anyone knows what this code means it would be

Mydata TP11-UFP F-MOT1-38/245

Electronics Forum | Mon Oct 25 11:20:52 EDT 2021 | bk

The 245 error is with your x belt motor not the x wagon motor. double check all the fuses on the back of the machine where your power comes in there should be 3 of them. if you haven't changed your blue cables in a while I would change those out. you

Need Help on MYDATA MY12 Initiate Hardware Error

Electronics Forum | Tue Jul 22 09:12:58 EDT 2008 | chiptargets

Hi, I posted a similar message yesterday, but I believe it did not make it through properly. I apologize. We have an error while trying to perform Initiate Hardware test. The error was "F-MOT1-25/205:MOVZ: Motorspeed Out of Control". The error, ho

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 13:51:51 EDT 2013 | shankar2013

acceleration is set to lowest. Ribbon cables were replaced, theta motor replaced. I also see a message pop up just after F-MOT1-26/156:MOVFI: MOTOR TIMEOUT / F-AXIS-182:C-AXIS NOT properly out when expected / 25v reads 3V. Now all these messages

Sm t t net
Previous 1 2  

f-mot1 searches for Companies, Equipment, Machines, Suppliers & Information

SMT feeders

High Precision Fluid Dispensers
Selective Soldering Nozzles

Wave Soldering 101 Training Course
2024 Eptac IPC Certification Training Schedule

Best Reflow Oven
Global manufacturing solutions provider

World's Best Reflow Oven Customizable for Unique Applications
design with ease with Win Source obselete parts and supplies

Low-cost, self-paced, online training on electronics manufacturing fundamentals