Electronics Forum | Thu Jan 03 21:43:20 EST 2002 | davef
Resistivity [1/ohm] readings are determined by the "cleanliness" that you desire to ensure the proper performance of your product. Check the fine SMTnet Archives for background. Contact USFilter [ http://www.usfilter.com/ ] for help.
Electronics Forum | Thu Nov 10 22:57:48 EST 2005 | davef
The recommended electrical resistance for flooring from ANSI ESD S 7.1 and ANSI/ESD-S20.20 is
Electronics Forum | Thu Sep 15 19:32:51 EDT 2022 | totech
I would like to Add that Mitch is very knowledgeable on this subject, I believe since 2008 this has been a topic of his .. different of low temp baking 40c 50c 60c vs 90c or 125c I do have some totech independent evaluation on the subject if you lik
Electronics Forum | Sat Sep 10 17:12:18 EDT 2022 | yannick_herzog
Hello, we use an oven to dry our MSL components after the floor lifes expires. The oven works at 40°C / 0.1% RH. The plan is to upgrade the oven from 40°C to 60°C to shorten the duration of the process. I have found a number of articles mentioning
Electronics Forum | Fri Feb 24 14:10:16 EST 2006 | rsmith@z-mar.com
My company is an ESD firm. I have tested many different floors and sell ESD flooring and other products. With that said, here are my thoughts. Unsealed concrete is porous and tests in the 10 6th-8th range here in the southeast where we have decent hu
Electronics Forum | Wed Mar 14 21:57:58 EDT 2007 | Dave Jurena
We are setting up a facility in China and would like to verify the resistivity reading on our Westek wash machine. The only tool we have at this time is a multimeter. The machine reads .570 Mohms and the MM reads around .25 Mohms at a probe distance
Electronics Forum | Thu Jan 15 03:20:59 EST 2009 | sachu_70
Hi Andrzej, I guess you mean peelable solder resist. Good idea to try during R&D, but certainly not a solution on production floor. Also, few constraints to be considered such as presence of entrapped air between component and solder resist, the natu
Electronics Forum | Fri Feb 24 08:49:55 EST 2006 | BGS
We have concrete floors. We check 28 locations every 90 days with a surface resitivity meter (calabrated) and Ive never seen a reading other than 10 to the 9th
Electronics Forum | Mon Jan 08 23:39:53 EST 2007 | raychamp007
HI Friend, My SMT Production Floor RH reading are 38%RH to 65%RH. It is within control or as per IPC/J-STD or orthers industries standard recommendation? Hope to hear comment from anyone. Thanks!
Electronics Forum | Thu Mar 15 02:49:30 EDT 2007 | Dave Jurena
Thanks, Mike.