Full Site - : fuji alarm (Page 7 of 10)

FUJI CP4-3 Nozzle Change Alarm

Electronics Forum | Fri Aug 01 06:54:22 EDT 2014 | tegel

Hi, I don't have any solution to the problem, but the component is an EMI-filter and not part of the machine. // Tegel

FUJI CP4-3 Nozzle Change Alarm

Electronics Forum | Fri Aug 01 09:21:28 EDT 2014 | jimmyboz

Does it error during nozzle center check, if so, manually switch all holders to small, try center again. It should do about 8 small nozzle centers before error, if so this helps rule out the 10th station, if not check the 10th.

FUJI CP4-3 Nozzle Change Alarm

Electronics Forum | Fri Aug 01 11:57:56 EDT 2014 | kurtiss

It turns out it was a misaligned fiber sensor on station 12?, the after rotation nozzle verification.

Nozzle errors

Electronics Forum | Sun Sep 11 02:33:07 EDT 2011 | johndoe0222

We are using Fuji CP iv-3 and keep getting "Nozzle size alarm and Nozzle position error." I was wondering what is wrong and how do I fix these errors? Thanks

FUJI CP4-3 Nozzle Change Alarm

Electronics Forum | Thu Jul 31 14:07:44 EDT 2014 | kurtiss

I found a bad solenoid and replaced it solenoid 15 on station 11. The machine is still erroring out. I also checked the holders and sensors and they seem to be ok. This error occurs when ever the machine tries to change nozzle sizes on any holder. T

Fuji CP 65 FRQ Servo Overflow

Electronics Forum | Fri Mar 02 18:44:43 EST 2018 | magergar

At boot there is an alarm that I can't get rid off Servo Alarm FRQ AXIS Servo Overflow I tried to calibrate it in mecha mode but the same error doesn't let me, it's there something I can do?

Fuji CP troubleshooting

Electronics Forum | Wed Jan 05 16:43:41 EST 2005 | mee13

what size feeder are you using there, when does this alarm occur :during prod?

Nozzle errors

Electronics Forum | Sun Sep 11 07:16:31 EDT 2011 | smellew

We are using Fuji CP iv-3 and keep getting > "Nozzle size alarm and Nozzle position error." I > was wondering what is wrong and how do I fix > these errors? > > Thanks > We are using Fuji CP iv-3 and keep getting > "Nozzle size alarm and Nozzl

Re: Cycle Alarm X-reach on CP6

Electronics Forum | Sun Jul 09 03:05:14 EDT 2000 | Ben

Hi Hermie, Did you perform a Servo-zero-adjustment and Gain calibration on the amplifier after replaced it ? This is necessary fine turning when replacing the amplifier. You had better ask Fuji service center for the procedure. Hope this help you.

IP3 X1 Encoder Alarm

Electronics Forum | Thu Feb 14 22:19:05 EST 2008 | ashley

hello Keith, the problem may be related to a faulty / dirty linear scale. kindly check on the yellow strip along the X axis. clean & clear the glass linear scale of debris & grease. for Fuji support & spare parts, please write to :- apexservice@