Electronics Forum | Tue Feb 11 15:31:10 EST 2020 | sumote
We have not used out tray handler in several years, and when I had a need arise the thing now throws a Servo Error "MTU1 ALARM [11081010]. There are 4 servo packs in the cabinet. When I try to initialize/zero out the machine the 2nd and 4th servo pa
Electronics Forum | Fri Feb 15 03:38:37 EST 2008 | keithej2
The X1 glass scale reader is bad. After cleaning it didn't help, we removed the read head and took the cover off. There is a cracked component (L1) and magic smoke/dust on the parts around L1. There's also a dead short on the two tiny wires that supp
Electronics Forum | Fri Oct 07 04:26:13 EDT 2022 | acouto
We are having an issue after performing a head cleaning. Error 0x0000D005 - "An error that can be cleared (alarm) has occurred at the axis" We are trying to solve this problem but every time we insert a head into the cleaning machine, it gives us the
Electronics Forum | Thu Sep 16 18:43:57 EDT 2010 | slwolbert
Hello Daxman, Thanks for the input. Yes, the CP2 is closely related to the CP4 and does have the analog servo amps as you deduced. I did a wiggle test on the connectors and found that the x-y-r servo amp alarmed right away and blinked the x axis a
Electronics Forum | Fri Apr 27 13:57:19 EDT 2001 | CAL
I agree "can't put teens with learner permits on NASCAR raceways and expect them to succeed" I am confused though....Once the program is sent to the machine the line computer is there just for line monitoring (Errors and alarms). The machine runs wi
Electronics Forum | Mon Mar 09 13:07:52 EDT 2009 | rodrigo
Hi all, Our IP-2 stop working during production with a Servo NG error. Turning it on and off just goes back to the same thing or "Turn servo power on" error message. I was checking the power for the servo amps and I found a 35VAC line that is missin
Electronics Forum | Tue Sep 14 17:15:30 EDT 2010 | daxman
Hi Steve, I don't have any experience with CP2's. Sorry .. hazarding a guess though... if they use the analog servo amps like they do in the CP4's, they had a bunch of trimmer pots on them. There is a procedure to zero them using the mecca check mod
Electronics Forum | Wed Jun 09 10:41:28 EDT 2010 | chrislyttle
We've been having some problems with out Fuji IP2E machine that we've recently bought from a company that is no longer operating here. Since installing it we've encountered a few problems with it starting up. To give you a quick breakdown of its be
Electronics Forum | Thu Mar 30 13:27:53 EST 2006 | bvdb
Just before Christmas we bought a used Fuji IP1 cheap. It took us a while but it's been working great for about a month. Yesterday the IP1 stopped after completing a board but before exiting the board out the conveyer. No error message, no alarm be
Electronics Forum | Thu Aug 03 19:34:17 EDT 2006 | davef
You might consider an oxygen monitor (or lack of oxygen monitor). A fast response-rate analyzer should be used. There are several types of analyzers on the market and each has different limitations. * If you are looking for a measurement ranging fr