Full Site - : fuji cp65 servo amp alarm (Page 4 of 5)

Servo Amplifier Alarm on Fuji CP4-3

Electronics Forum | Thu Nov 04 02:14:19 EDT 2010 | adriana

Yes, we are checked all power supplies and is OK! Many thanks!

Servo Amplifier Alarm on Fuji CP4-3

Electronics Forum | Wed Nov 03 14:44:45 EDT 2010 | aj

have you checked your power supplies are all giving correct outputs?

Servo Amplifier Alarm on Fuji CP4-3

Electronics Forum | Thu Nov 04 07:05:25 EDT 2010 | aj

happy days os

Servo Alarm on FUJI IP-2 (MTU unit)

Electronics Forum | Thu Sep 15 10:25:13 EDT 2005 | lyrtech

Hi, this morning we got a "servo alarm MTU" on our FUJI IP-2. On a servopack, I see an " Over Current" error. what does it mean? I don't know hoe to check that. Can anyone help me? Thanks a lot.

Fuji FCP 2 Check Servo issue

Electronics Forum | Tue Sep 21 18:46:24 EDT 2010 | slwolbert

Greetings: > > I am having 'Check Servo' issues > with an FCP 2 4000. It will zero set but given a > few minutes afterwards, the check servo alarm > sounds. > > At times the X/Y table will 'coast' > back to beginning position, like the power

Servo Alarm on FUJI IP-2 (MTU unit)

Electronics Forum | Thu Sep 15 16:02:20 EDT 2005 | jdengler

Over Current means the motor is drawling too much current. Check for a jam on that axis, bad wire, bad motor, bad servo amp (yes the amp can go bad and make it appear that the motor is drawling too much current). Jerry

Servo Amplifier Alarm on Fuji CP4-3

Electronics Forum | Thu Nov 04 06:46:19 EDT 2010 | adriana

We find the problem on Servo Pack for F theta axis .The component QM20TD-H Mediu power Switching is damaged! Many thanks!

Fuji FCP 2 Check Servo issue

Electronics Forum | Thu Sep 16 18:43:57 EDT 2010 | slwolbert

Hello Daxman, Thanks for the input. Yes, the CP2 is closely related to the CP4 and does have the analog servo amps as you deduced. I did a wiggle test on the connectors and found that the x-y-r servo amp alarmed right away and blinked the x axis a

Fuji FCP 2 Check Servo issue

Electronics Forum | Sat Sep 11 08:19:54 EDT 2010 | slwolbert

Greetings: I am having 'Check Servo' issues with an FCP 2 4000. It will zero set but given a few minutes afterwards, the check servo alarm sounds. At times the X/Y table will 'coast' back to beginning position, like the power has been cut to the

Re: Cycle Alarm X-reach on CP6

Electronics Forum | Sun Jul 09 03:05:14 EDT 2000 | Ben

Hi Hermie, Did you perform a Servo-zero-adjustment and Gain calibration on the amplifier after replaced it ? This is necessary fine turning when replacing the amplifier. You had better ask Fuji service center for the procedure. Hope this help you.


fuji cp65 servo amp alarm searches for Companies, Equipment, Machines, Suppliers & Information