ODD FUJI IP3 PROBLEM

Electronics Forum | Tue Oct 16 01:29:11 EDT 2012 | dman97

I have a very odd problem with my Fuji IP3 and was wondering if anyone can help. Any part that gets picked from the MTU will fail vision recognition. After turning on the vision trace data, I can see that the IP3 is looking for the part to be rotat

place BGA by FUJI IP3

Electronics Forum | Wed Apr 24 11:02:01 EDT 2002 | cnoonan

This may not be the answer you were looking for, but I have worked for serveral leading technology companies and we used vision (type 10)on IP3, and QP3 machine and never had a problem with placement issues.

Fuji IP3 Head squealing

Electronics Forum | Wed Dec 20 07:08:51 EST 2006 | cyber_wolf

We have had this happen. The Z-ball screws do go bad in IP3's. We replaced the ball screw and the problem went away. As mentioned improper belt tension will cause the servo to make loud noises. But if you say the movement is rough, then the ball scr

Re: FUJI IP3

Electronics Forum | Sat Dec 12 12:25:14 EST 1998 | David Lombard

| My Fuji IP3 keeps getting the Check Sensor Error. | What is the problem? | This problem is caused by either of two things. First the vacuum chuck get dirty and needs to be cleaned "PM". If the problem is persistant the vacuum chick has worn down

Re: FUJI IP3

Electronics Forum | Sat Dec 12 12:26:08 EST 1998 | David Lombard

| My Fuji IP3 keeps getting the Check Sensor Error. | What is the problem? | This problem is caused by either of two things. First the vacuum chuck get dirty and needs to be cleaned "PM". If the problem is persistant the vacuum chick has worn down

Fuji IP3 Problem

Electronics Forum | Tue Aug 22 16:33:59 EDT 2006 | aj

I have also seen this error on the machine and it was related to a dodgy PD. aj...

Fuji IP3E Start up problem

Electronics Forum | Thu Jun 10 13:41:59 EDT 2010 | cyber_wolf

The transformer was probably wired wrong and you done blowed ol bessie up.

Fuji IP3 clamping problem

Electronics Forum | Fri Mar 08 12:22:18 EST 2002 | pr

Have you contacted Fuji? I believe we had the same situation a while back and (I think) it was a proper setting and not a sensor problem. A tech. can probably walk you through it over the phone. good luck, pr

Fuji IP3 Problem

Electronics Forum | Wed Aug 23 14:44:07 EDT 2006 | johnw

They are various way to debug this problem, try booting into mecha check, The cpu wouldnt cause a vp error all that is related to the VP are 3 cards the gognex the vp card and the memry backup card. If this fails print out the trace machine code and

Fuji IP3 Problem

Electronics Forum | Sun Aug 20 02:31:18 EDT 2006 | daxman

Last week, when we turned on our IP3, we received an error on our IP3, which read "Fatal Error with VP Turn Power Off" We had been running product the day before, and the day after we received this error. The function keys are locked and will not w