Electronics Forum | Wed Oct 17 14:26:30 EDT 2012 | dman97
With that said, do you happen to have the calibration procedure for the MTU? I already have the X0 Y0 jig. Just need to know where exactly I am supposed to calibrate with regards to the actual trays.
Electronics Forum | Mon Jul 04 13:43:38 EDT 2022 | richardcargill
is it a specific part you're having the problem with, or does the fault manifest on a number of different ones ?
Electronics Forum | Wed Jan 10 21:03:02 EST 2024 | madisreivik
Vision error found: YOU MUST CHANGE LAMPS SOMETIMES ! Also, the camera front-glass (with the cutout) must be correctly positioned :) Still looking the Q error on left head. Probably mechanical problem...
Electronics Forum | Fri Jan 12 15:32:53 EST 2024 | madisreivik
Indeed I found some vacuum problems, one replaced small hose was not fitted correctly. Lets see if that helps :) Great thanks ! Also, Travis, do you have any information how to adjust the milk-plexiglass slitted covers on line scan cameras ?
Electronics Forum | Tue Dec 06 19:44:10 EST 2011 | comando
Hello every one! I need help with a misaligned theta at plcc44, the machine is a IP3 smd3, firmware 2.99, vision card 4400 and both camera type YD2048N on label but in Proper data is set 2 (I don't know if this is right) we use Fuji flexa, Back Lig
Electronics Forum | Wed Jun 09 10:41:28 EDT 2010 | chrislyttle
We've been having some problems with out Fuji IP2E machine that we've recently bought from a company that is no longer operating here. Since installing it we've encountered a few problems with it starting up. To give you a quick breakdown of its be
Electronics Forum | Wed Mar 20 13:49:15 EST 2002 | cabjerk
Hi All; The following is from our Support people who worked with Fuji on the problem; Last week Luke Mittur and John Gudel were in from Fuji to address the IP3 issue outlined below. The problem ended up being that the table "up" and table "dow
Electronics Forum | Wed Mar 13 14:17:03 EST 2002 | dougt
Are these sensors the reflective type? Maybe when the board is unclamped and it goes over the sensor it is seen, and then when it is clamped (raised) it is now out of the range the sensor was set for. That should be easy to adjust. A problem I've
Electronics Forum | Tue Mar 19 16:55:54 EST 2002 | Steve E ( Fujiamerica )
This problem happens when a dark part is placed where the main conveyer stop sensor is located.The machine does a board check ( back to loading pos ) . If a part is under the sensor it absorbs the beam and the machine thinks there�s no board. The ta
Electronics Forum | Tue Aug 22 10:51:49 EDT 2006 | rmitchell
Hi, Hope your machine is back up and running. Are you sure it is not program or PD (part library) related? Try power off and back on and delete the machine program from the machine. Then- Power off and back on and see if the VP error is gone. It