Full Site - : gsm 265 board stop (Page 8 of 13)

DEK265gsx inconsistency in management f

Electronics Forum | Thu Feb 22 23:27:14 EST 2007 | dekhead

If protocol is already manual, does conveyor start when "RUN" is pressed (without board on rail)? Or does it not start until board is placed? Try running UL protocol as "No FMI", put in run without board on rails, place board, press "Confirm". Board

Backing up GSM - Segment Repair importance...

Electronics Forum | Mon Mar 21 21:38:40 EST 2005 | pmd

You do not need to back up segrep. This is only used for boards currently on the machine whenever the machine encounters a palm down or soft stop. It only contains what is mounted and or not mounted on that board. No System infomation is contained in

GSM Zeroing problem

Electronics Forum | Thu Jul 09 15:17:48 EDT 2015 | goodting

Thanks for the inquiry. We used MCD (Motion Control Dia) tool to verify if that is caused by VRM board. No respond(I means the related axis was off) was detected. we swapped that board to other machine, the VRM card was good.... X axis was stopped, t

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Thu Sep 26 13:55:54 EDT 2019 | ttheis

One of our GSM1 machines occasionally stops running in the middle of a program and I haven't been able to figure out what is causing it. When the issue occurs, the "BM" (bus master) light on the SYS68K card drops out (turns off, no activity) the boa

DEK265 alignment out of range

Electronics Forum | Thu Mar 19 03:07:31 EDT 2020 | weglimir

We have DEK265 and a problem with few projects. Normally it works great, but sometimes we have an issue with Alignment out of range error. Currently we have a project where after fiducials configuration in step mode printer shows an error : Align

GSM Spindle Height / Zaxis calibration?

Electronics Forum | Mon Sep 20 20:43:19 EDT 2021 | ttheis

One of our GSM machines started having an issue with "spitting" parts onto the board / blowing them around. I determined the problem be that spindle #2 on our flex head is not touching the parts all the way down to the board. It is stopping just abov

DEK265gsx inconsistency in management f

Electronics Forum | Fri Feb 23 08:51:38 EST 2007 | dekhead

Are you saying that it works in "no fmi" mode, but not in manual? Please tell me how it works in both. I'm asking you to change things to ascertain the problem, not as possible solution... if you can't get the board to stop in the correct position,

DEK265 alignment out of range

Electronics Forum | Thu Mar 19 15:28:34 EDT 2020 | emeto

You are programing something wrong or your image is not in the center of the stencil. On DEK machines you can move a lot in Y by offseting the image in the program. In X machine can move +_5mm. Now, sometimes there is a way around this as well if yo

GSM machine stops responding to VME during production, CLOCK01.SYS failed to install

Electronics Forum | Fri May 06 20:22:02 EDT 2016 | ttheis

I found this in the Force SYS68K CPU-30 manual: ------------ "BM" LED If the CPU board is the current VMEbus master, the green BM LED is lit. This provides the user with a convenient visual indication of the status of the VMEbus. ------------ So th

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Fri Oct 11 09:49:07 EDT 2019 | ttheis

FYI I did try logicomm but the log files were empty. There must be something wrong with my connections from the force board to the EPC. I'll keep investigating. I also swapped the EPC to see if that makes any difference.