GSM machine stops randomly; "BM&quo

Electronics Forum | Wed Dec 23 19:50:28 EST 2020 | ttheis

Thanks; I have a spare power supply coming as well. I will start by swapping dc-dc converters first and if the problem persists swap the pdp power supply. I'll report back what I find.

GSM machine stops randomly; "BM&amp

Electronics Forum | Fri Jan 29 18:47:35 EST 2021 | ilavu

The error in the attached picture(FCFF1043) is for 16 I/O card located in CIO slot one for board transfer. May be thats when your PDP supply drop voltage. If problem comes back, look at that card and/or connection and/or cable.

GSM machine stops randomly; "BM&amp

Electronics Forum | Fri Jan 29 22:26:09 EST 2021 | ttheis

Thanks for the heads up. I suspect it is due to power dropping out to the IO chassis and other devices connected to the pdp. This is the first logicomm capture I have for it so I don't have other messages to compare it to. Machine has been running al

GSM machine stops randomly; "BM&amp

Electronics Forum | Fri Feb 26 02:41:10 EST 2021 | ttheis

We have been running the machine for about a month after replacing the pdp power supply. We have not had a repeat of the problems since. I believe we can consider this issue resolved. Failing pdp supply was a known issue in the uic kb.

GSM machine stops randomly; "BM&amp

Electronics Forum | Fri Jan 29 13:25:43 EST 2021 | ttheis

Update: I have replaced both dc-dc converters without any improvement. Observing the issue again yesterday I was able to see more of the problem. Logicomm reported a bus error at fcff1043 running "butt" (photo attached.) The DC power ligh

GSM machine stops randomly; "BM" bus m

Electronics Forum | Wed Dec 23 12:57:59 EST 2020 | ilavu

Check Power Distribution Panel Power Supply. No output or output too low for 24V, 15V, and 12V. Also, LED's on PDP LT6, LT7, LT8 , LT9, LT10, LT11 don't turn on at all, even though all fuses test OK for continuity.

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Fri Sep 27 02:01:31 EDT 2019 | dilogic

Did you try "Logicomm" debug procedure? It might give you a hint...

GSM machine stops randomly; "BM" bus master light out

Electronics Forum | Fri Sep 27 14:26:57 EDT 2019 | ttheis

Hi Deni- Thanks for the suggestion I will read up on Logicomm and see what it gets me.