Used SMT Equipment | Board Cleaners
Speedline Electrovert Aquastorm 200C - LOADED AUCTION ITEM: www.xlineassets.com - AUCTION STARTS SOON! AS2C-20001 07/22/08 1.0 EA 480V 20in Process Width PW-FR FLOWMETERS Dual Hurricane Chemical Isolation Package 20 HP Pump For Wash
Used SMT Equipment | Soldering - Wave
Speedline / Electrovert Electra Wave Solder System; 11/2007 Vintage; 20in Process Width, 208 volt, VVL Fingers, Exit Cooling Fans, 3 Bottom Convection Preheater, 2 Top IR, Heater; Servojet Spray Fluxer;Ffull N2; N2 Short Tunnel Option; Titanium Main
Used SMT Equipment | Board Cleaners
Speedline Electrovert Aqueous Cleaning System Brand: Speedline Model: Aquastorm 200 (Torrid Zone) Serial #: 480409 Year: 2004 Type: In-line Cleaner Prewash Module: 14" (36cm ) section Vee Jets staggered nozzles, 2 upper and 2 lower spray m
Used SMT Equipment | Board Cleaners
Speedline Electrovert Aqueous Cleaning System In-line Cleaner Model: Aquastorm 200 (Torrid Zone) Year: 2004 S/N 480409 Prewash Module: 14" (36cm ) section Vee Jets staggered nozzles, 2 upper and 2 lower spray manifolds Valve switching to div
Electronics Forum | Thu Aug 30 11:59:00 EDT 2001 | Spanky
Hey all, I have 3 questions about reflow. Hopefully someone can help me. 1. I am having a problem. I set the peak at 230 and my mole thermocouples are telling me the temp in that zone gets to 237. How is this possible even if the thermocouple
Electronics Forum | Thu Apr 06 14:27:04 EDT 2023 | jdengler
Hi everyone, I am looking for a schematic in PDF for an OmniFlo 7 manufactured in 2003. Our hard copy has gone missing. Specifically I am looking at which SSR controls zone 2 bottom heater. Thanks, Jerry
Electronics Forum | Thu Apr 06 16:08:17 EDT 2023 | jdengler
Thanks for the effort. I have the maintenance and operations manuals in PDF so they are not missing. It looks like the only place it will show which SSR controls which heater will be in the schematic.
Electronics Forum | Fri Jun 23 12:21:29 EDT 2017 | rgduval
I'm going to guess that you've tried Speedline with no success. They're awfully annoying about their older machines. Things to check: - Thermistor for the zone working properly? - Opto for the zone working correctly? - Heaters working correctly? -
Electronics Forum | Thu Apr 01 21:18:31 EST 1999 | Chris Kelly
Glenn, There are both very good VOC-Free fluxes as well as alcohol based fluxes out there. This should be your primary focus if you are so lucky as to have to opportunity to actually select a flux! The use of nitrogen will benefit any no-clean pro
Electronics Forum | Fri May 15 21:39:48 EDT 2015 | jlawson
Reflow.. 1.Rehm (Germany) - Best in Class Best overall process stability heating system ( Alot of makers have started to copy there VX heating arrangement ). COnveyor chains can be a bit more attention in terms of maintenance on rehm , but if foll