Full Site - : homing error (Page 8 of 14)

programmer or technician of universal hsp 4796a, or 4796b

Electronics Forum | Thu Mar 01 19:23:41 EST 2007 | SWAG

I could be wrong but I think the use for alternate feeder axis is a way of stopping the carriage so it does not always return to home every time an error condition exist. Saves on time and wear and tear on the machine. As for alternate carriage, I

DEK Horizon Screener

Electronics Forum | Sun Apr 17 18:22:18 EDT 2022 | dekhead

Please clarify what you mean by "bouncing". Small up and down motions around home position? Full stroke of table movement up and down? Or somewhere in between? Does it start as soon as servo power is applied? Or not until table home movement is initi

Re: Registration

Electronics Forum | Tue Feb 16 15:33:13 EST 1999 | Clifford Peaslee

| Cliff | | Each time I attempt to edit my account, or register the company, I get a failure message.... | | OOPPS type message. | | Wayne | If at first you don't succeed... try going to account manager home I am setting up the error scree

Yestech AOI experiences

Electronics Forum | Mon Jan 31 09:31:31 EST 2011 | dwonch

Hi all, We've had a Yestech F1 system for several years now. Overall we are happy with the machine, fast and easy to program. Good false call rate and few misses. Now for the issues. We have two in particular. 1. Software crashes - these general

Samsung CP 45 NEO, servo motors

Electronics Forum | Fri Mar 22 03:19:43 EDT 2019 | bukas

well, in video shown it looks like #1 motor drives head #1 upwards but does not detect home sensor being triggered. and then you get timeout error, head not being able to reach the position ( machine not registering it has reached position). since yo

Universal GSM 2

Electronics Forum | Mon Oct 20 10:08:42 EDT 2014 | rgduval

Had someone in from the broker that we bought this machine from, and he did some poking around. We've learned some things, but, unfortunately, are still no closer to getting the machine running :( We discovered (based on double checking other machi

Samsung CP40 Z height motor alarm detected Error Code 1523

Electronics Forum | Mon Jun 12 21:16:41 EDT 2017 | kahrpr

you can not just take the motor off and change it. the motors have a home pulse singnial. the motor has to be in a certian position the home pulse position when the flag hits the sensor. When you remove the motor you have to mark the motor gear when

Samsung CP40 Z height motor alarm detected Error Code 1523

Electronics Forum | Fri Jun 09 07:32:13 EDT 2017 | bukas

it sounds to me like a home sensor. try adjusting sensitivity if possible. move head manually to determine position at which home sensor is activated

DEK 265 Horizon Servo Following Error

Electronics Forum | Fri Jan 05 12:02:28 EST 2018 | ilavu

Camera works fine from home to ref. position to fiducial1 and 2. Problem shows up from home to board stop. AC voltage between AC1 and AC2 is 41.7 and during move it drops to 41.5.

Problem with y-axis Yamaha84 SMT mounter

Electronics Forum | Tue Oct 25 22:54:55 EDT 2005 | KEN

sorry. re-read your post. The problem is the home sensor relative to the home pulse. You're catching the wrong home pulse. a 10mm offset sounds about right for a 360 degree error. You need 50% +/- 15 % to ensure you always zero to the same phys


homing error searches for Companies, Equipment, Machines, Suppliers & Information