Mydata Hydra tool reference mark error

Electronics Forum | Mon May 06 19:21:39 EDT 2013 | amelby

We had that problem on our M12. There were a few > components that had gotten dropped into the > camera area as the hydra head past over it. Our > MY12 has a knob towards the front of the machine > in direct line with the camera. Pulling this

SIEMENS S20 Y axis - correct zero pulse not found

Electronics Forum | Mon Jan 28 13:40:53 EST 2019 | liquidspacie

Hello, I'm trying to fix this error and what I've done so far I cleaned (no scratches) measuring scale and swapped cards (gantry 1 & 2) and cleaned scale reader sensor. There are no spare parts, I'm just trding to narrow down the cause. Any suggestio

Quad 4c not placing components

Electronics Forum | Thu Sep 05 07:14:16 EDT 2019 | smrsteve

Hello Bobpan, Thanks for the suggestions. Sorry I didn't reply yesterday as I'd gone home - I'm in the UK, so I'm guessing there's a time difference. Okay, I found the control to turn off the vacuum verify - it's SHIFT - SWITCH/VERIFY. Makes no di

Skew error at axis G1F-Y

Electronics Forum | Wed Oct 26 05:44:39 EDT 2022 | spacecase

Hello all, I was looking at a Samsung SM421-f component placing machine and it's throwing up an error that was not described in the troubleshooting guide. Anytime I try to move the camera or home it the machine stops and the screen says that a skew e

Contact 3AV-100. PCL-240AK position Error. Machine not hommed

Electronics Forum | Fri Jan 28 15:22:07 EST 2011 | dougt

The PLC240-AK is an IC on the stepper board used to control all the stepper driven axis. I don't remember which axis are driven by stepper motors, possibly the table (x axis). Which axis acts wierd or doesn't move when you home the machine?

F4G CP4 Optimizer: Cycle time table file not found?

Electronics Forum | Thu Dec 09 13:22:24 EST 2010 | rodrigo

Hi All, I'm trying to use the F4G CP-4 optimizer. I cleared all the issues I was having except for this error I get at the end: Execute, 2030: Cycle Time table file not found I see a file in one of the folders named CP4_CYC.TBL but I'm not sure if

Please help. MPM SPM printer can not boot up

Electronics Forum | Sat Jun 21 11:00:32 EDT 2008 | 1036

We recently bought an used MPM SPM screen printer. The system can not boot up correctly and terminates the program finally. During the computer booting up, I can see error massages "mouse could not be found", "abnormal program terminated", "trap 0".

Help CP40CV Contactors Not Engaged,Safety Relay K1 K2 not on?

Electronics Forum | Sun Jan 17 10:27:01 EST 2021 | ecogroup

Thanks for replying Bukas...few days prior we found out it was the conveyor IF board. Changed it, all the contactors now engage. But now have these errors: Opened [SYSTEM] file is created by #1 machine. No command resonse from handler. (0x1000)

GSM Calibration; Z-axis not touching down to pickup calibration card.

Electronics Forum | Tue Jul 19 00:34:36 EDT 2022 | ttheis

We found that the "Z offset" on the head was altered relative to the other machine and restoring defaults made both machines display the same settings. Once defaults were restored for the second machine, it began picking up the card from the tray and

help GSM2 Spindles error: All spindles safe sensor not seen for head

Electronics Forum | Wed Mar 19 19:19:41 EDT 2014 | dave222

thank you for taking the time to look at this post. hopefully someone can help. I have a GSM2 Q block with a Flexjet 7 spindle head. a couple of days ago the machine encounter this issue while zeroing. the issue is with head 2 on beam 2. on the di