Full Site - : humidity cabinet (Page 19 of 26)

Humidity control

Electronics Forum | Mon Nov 12 17:14:53 EST 2001 | dason_c

We have under evaluation one of the dry cabinet and it can drop down the humidity to 10% within 20 minutes from room. You can check this web site, http://www.cabiusa.com Dason.

Humidity question

Electronics Forum | Tue Oct 21 14:15:05 EDT 2008 | ccouture

Mariss, I would run a power analyser on your oven to see the real power consumption during warm-up and during production. Then you would be better able to decide how much money to invest in a humidity controled cabinet big enough to contain your dail

PCB & MSD Component baking oven

Electronics Forum | Tue Dec 07 07:26:50 EST 2010 | grahamcooper22

In an oven over 100 C any moisture will escape through vents. There will not be huge volumes of moisture in the oven when you are baking components so it should easily escape through vents / holes in the system leaving you with a humidity of near zer

Re: Popcorn effect with PBGA

Electronics Forum | Wed Apr 05 08:51:25 EDT 2000 | Wolfgang Busko

Emmanuel: Popcorn effect is mostly caused by entrapped moisture in the components package material. Plastic ICs are known for absorbing and storing moisture when exposed to normal factory conditions. They should be stored in an moisture reduced envir

Humidity question

Electronics Forum | Tue Oct 14 19:56:35 EDT 2008 | davef

Why not use a cabinet like those used for limiting the exposure of misture sensitive components to humidity?

MSD Storage - Dry Environment

Electronics Forum | Fri Jul 17 01:39:07 EDT 2009 | grahamcooper22

Hi, it is not necessary to store MSDs in nitrogen to stop them absorbing moisture, just a dry environment. Nitrogen storage is good for storing devices for many years as it reduces the oxidation of the solderable surfaces. Best option for storing MSD

MSL Project

Electronics Forum | Fri Mar 09 04:10:18 EST 2012 | grahamcooper22

Hi, I've been supplying Totech dry cabinets in the Uk for 10 years and in that time I've realised the only places to find the correct MSL level is on the dry pack the devices are shipped in or by spending hours on the internet or speaking to the devi

BGA Placement Process

Electronics Forum | Fri Mar 26 10:35:52 EDT 2010 | grahamcooper22

Hi Krish, thanks for your detailed reply. Sorry I assumed you may be using a solder paste to solder the BGA to the pcb. Either solder paste or Gel flux is best for resoldering BGA to pcb. Are you using Gel flux ? Most popular long term storage for mo

MSD Storage - Dry Environment

Electronics Forum | Mon Jul 20 04:37:23 EDT 2009 | jdumont

We have used some sealed steel cabinets and a nitrogen generator (Balston 75-79 model) for about a dozen years with no issues at all. Humidity levels average 1% - 5%. We also just bought a couple of XDry (Totech) desiccant cabinets (XD2-1104-02) for

Depanneling Problems

Electronics Forum | Thu Feb 17 18:13:31 EST 2011 | SheanDalton

Humidity, Juliano? Try drying the boards pre solder; oven or dry storage cabinet. If this works, Eureka has good desiccant dry storage cabinets, http://www.atekllc.com. Shean Dalton www.fhpreps.com