Full Site - : ionograph correlate ion chromatography (Page 2 of 3)

Ionograph Testing

Electronics Forum | Fri Jan 06 09:15:34 EST 2006 | sarar

I would suggest that it would be helpful to perform ion chromatography analysis on some of the boards that have failed your ionograph tests as well as some boards that have passed. This will tell you exactly what ionic species are present on the boa

SIR starting point...?

Electronics Forum | Mon Oct 21 22:15:36 EDT 2002 | davef

First, SIR data is heavily dependant on the test pattern selected. Be very careful when comparing the results of resistance readings taken from different geometric patterns. Second, if yer talkin': * Bare boards, yupper. * Finished assemblies impor

changing from no-clean to clean

Electronics Forum | Wed May 22 08:43:40 EDT 2002 | pjc

I have experience cleaning NC for military boards. The reason for cleaning the NC is due to conformal coating requirements. Zestron Vigon A200 and Atron AC 100, as well as Petroferm Hydrex DX have both been effective at cleaning Alpha UP78 NC paste.

PCB Trouble shooting Lab

Electronics Forum | Tue Apr 17 09:38:04 EDT 2001 | CAL

With some help from our good Friends at Agilent Technologies our RF Lab includes testing up to 100GHz. Equipment includes Vector network analyzer, signal analyzer, dual channel power meter, noise filter meter, advanced impedance analyzer (including

White Residues

Electronics Forum | Wed Aug 17 14:18:11 EDT 2005 | ppwlee

Dave, Answers to your questions: * From your pictures, the white residue appears to be only on the solder mask. Is that correct? If not, what is the location [eg, solder, nonsolder/nonmask areas] of the residue that doesn't show well in the pictur

Re: Criteria for the Omega Mete from Alpha Metals Inc.

Electronics Forum | Mon Jan 08 20:57:52 EST 2001 | Dave F

Are you talking about bare board cleanliness or assembly level cleanliness? Bare board cleanliness is still primarily measured by resistivity of solvent extract (ROSE) using instruments such as Omegameters and Zero Ions. What is considered as "acce

Contamination test

Electronics Forum | Mon Jul 30 21:03:44 EDT 2001 | davef

You should specify the level of res based on the effect of the res on the end-use of the product. J-STD-001 defines cleanliness requirements for ALL flux types, including water soluble and no-clean that you mention. 1 There is no equivalency betwee

omega meter

Electronics Forum | Wed Mar 06 21:16:17 EST 2002 | davef

�What does 5 micrograms of chloride mean to me?� * With SIR testing, you can show no detrimental leakage currents under humid conditions, no corrosion, no metal migration, which are the big factors in figuring out electrochemical reliability. People

Electromigration Testing

Electronics Forum | Thu Jul 01 10:24:31 EDT 2004 | davef

There is no specification for �Ion Chromatography for Ionic Cleanliness�. The performance of your product in your customer use environment determines the level that you select. The good part for you is that have at least one pole that you can put i

IONIC CLEANLINESS SPEC FOR BARE PWBs

Electronics Forum | Sun May 09 16:25:00 EDT 2004 | gabriele

Military and most commercial standards requires > post-soldered boards to measure less than 10 > �g/in of NaCl (14 when using an Omegameter, 20 > on a Ionagraph, and 37 on a Zero-Ion). > > As Dave > stated, 6.5 �g/in of NaCl is called out in >


ionograph correlate ion chromatography searches for Companies, Equipment, Machines, Suppliers & Information

used smt parts china

High Throughput Reflow Oven
See Your 2024 IPC Certification Training Schedule for Eptac

Training online, at your facility, or at one of our worldwide training centers"
2024 Eptac IPC Certification Training Schedule

World's Best Reflow Oven Customizable for Unique Applications
Pillarhouse USA for handload Selective Soldering Needs

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...