Electronics Forum | Thu Dec 11 09:15:06 EST 2014 | sreejhu
Hello Sir, Thanks for your reply. i just got a mail from the DIMA service group and they said the Oven setting is as follows: Max temp settings in each zone (Which is not the temperature on your product, but close to where the air flow comes out of
Electronics Forum | Wed Dec 10 16:14:37 EST 2014 | jimpat
The 300 degrees is the temperature as measured at the sensor. The actual air temperature just above your PCB may actually be much less. If the oven is properly calibrated then the 300 should represent air temperature at the board but I have seen ma
Electronics Forum | Wed Dec 10 15:27:14 EST 2014 | sreejhu
Thanks for your reply!! But i dont understand the 300 degree is okay to for lead free process
Electronics Forum | Mon Dec 22 18:10:44 EST 2014 | sreejhu
What do you mean by solder in ROHS. Can you please explain me little bit. Is that really important while doing lead free process. Also, please tell me wether a 8 zone (4 bottm and 4 top) reflow oven with 300 degree max.. Is good to do the lead free
Electronics Forum | Fri Feb 15 15:55:58 EST 2008 | pjc
This is from the OmniFlo 5 Engineering data sheet: EXHAUST SPECIFICATIONS: STANDARD AIR OPERATION: - Load-end: 150 cfm (255 m3/hr) at the 4� (102 mm) stack (minimum requirement) - Unload-end: 300 cfm (510 m3/hr) at the 4� (102 mm) stack (minimum req