Electronics Forum | Thu Aug 25 07:43:24 EDT 2016 | claudea2
We have been having a recurring error on one of our Quad 4Cs. When it picks up the first of 8 47uF SMT capacitor it stops with a limit error. If we do 2 consecutive function 30s, the problem goes away until the next board. The first function 30 re
Electronics Forum | Thu Sep 08 15:45:21 EDT 2016 | claudea2
Thanks Bob, I will change the z-rod just to make sure. It is a tall part read at 180. The nozzle height bugs me because we have 3 machines and the first one has a nozzle height of 238 while the 2 others around 200. I am thinking this parameter may ad
Electronics Forum | Thu Aug 25 08:22:41 EDT 2016 | bobpan
If I have to guess then I would say the machine is first picking up a larger nozzle to pick up this part.....the nozzle is not seating on the z-rod correctly and causing a problem. Check to make sure the nozzle is being mounted correctly. You may als
Electronics Forum | Sun Oct 12 22:08:34 EDT 2014 | cusackmusic
I just got a used AP/C which I guess is also called an AP25? After fixing a few obvious issues, I powered it up, and get a hardware limit error. I have verified that none of the axis are near their limits. Without a manual, I'm not sure where to go
Electronics Forum | Mon Oct 20 15:28:22 EDT 2014 | island2013
We've got a set of manuals here for the AP series. If you would like to borrow them email me.
Electronics Forum | Tue Oct 14 10:52:35 EDT 2014 | swag
Can't help you with the manual but do have some tips: If it was shipped, it's possible someone tied axis or blocked stuff for shipping. Look for that. Look for bent sensor flags + go into I/O and check to see all sensors you can find are working.
Electronics Forum | Sat Oct 18 22:41:54 EDT 2014 | pfifla1
Can't help you with the manual but do have some > tips: If it was shipped, it's possible someone > tied axis or blocked stuff for shipping. Look > for that. Look for bent sensor flags + go into > I/O and check to see all sensors you can find a
Electronics Forum | Tue Oct 01 18:44:24 EDT 2013 | richardconnell
Hi, I have limited capability on the Z axis. The axis will home to the mechanical switch limit and then drop to a point which I asssume to be the fiorst zero point below the mechanical switch limit. Then it gives the error. There is power to the mo
Electronics Forum | Mon Sep 30 16:36:00 EDT 2013 | richardconnell
I have a Universal Instruments Corporation TAB Bonder. Oldish machine. Initial fault on machine : - "Axis Head 1 Z DAC Limit error during move absolute command" Other fault seen after we reset power, Zeroed axis etc. - Axis Head 1 - Z error not re
Electronics Forum | Tue Oct 01 17:56:10 EDT 2013 | swag
I'd take a look at the power supply for the failed axis and see if it's still working. I've also seen encoders fail on motors but it's rare in my experience. Usually it's a power issue.