MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Thu Oct 11 00:11:49 EDT 2018 | mk15

I am looking for some help for where to look to fix this MY15E problem. We started the machine after the weekend and this error code comes. F-MOT-MSETDYN z/3: Upper end point outside limit. Any suggestions? Thanks

Axis head error

Electronics Forum | Mon Jul 18 07:11:37 EDT 2005 | geb

Does anyone know what an "Axis Head 1 Theta DAC limit error during Move Absolute Command" may mean? It occurred during production. I have checked through the board's program for errors but cannot see any.

Topaz X error

Electronics Forum | Tue Feb 12 11:26:31 EST 2019 | aldrich17

Does anyone have any info. on an "E869" error code on a Phillips Topaz X SMT machine. Error screen shows "Nozzle down limit sensor is off in A-table YV100X:N2323 YV100XT:n2223 Please check sensor and remove to the cause of this sensor being off.

Comet Philips machine error

Electronics Forum | Wed Nov 16 09:33:39 EST 2005 | SuMoTe

I can't help you with most of that, but heres a starting point. "L013: 2nd limit over" means that one of your axis is showing outside operating boundries, as in placement head is too far forward. Make sure all your devices are not pushed out to thie

quad 1000 error

Electronics Forum | Wed Feb 23 15:19:49 EST 2005 | Dilbert

I don't work on quads but I can give you some things to look for... Each of the moving axis work off a motor that is controlled by a "drive". Some of these drives have a fault or error output that is connected to the motion controller. One of your

error 117:Overflow on CSM84

Electronics Forum | Sat Dec 01 18:08:03 EST 2007 | jmelson

Hello, I just ran into a crazy problem with my CSM84. I did a batch of one side of a board, then loaded the program to do the top side, and it stops with the head over the 3rd component's feeder, and reports error 117:overflow. The maintenance manua

MyData F-MOT MOVESLOWMOVE HYDRA error

Electronics Forum | Tue Apr 02 14:56:30 EDT 2024 | kingkelvin

Hi all - my problem is a bit worse now - I can get all hydra tests to pass in extended service, except indicator levels at current 7 a bit high past 190 limit at ~210-220 - other than that hydra bank re-installs OK - but still it makes a bad hitting

Universal Advantis Y1 axis error code 10201

Electronics Forum | Fri Jul 07 17:17:43 EDT 2023 | ttheis

We swapped the Y1 and Y2 pc800 controllers with no change. We swapped out the UIMC III-I cards from another machine with no change. VRM amps all look OK, no errors. The machine moves the head both in the x and y directions during the zeroing attemp

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 19:32:09 EST 2020 | SMTA-Alex

The fact, that your Hydra head goes up and then starts moving slowly, means that it didn't find the limit. Since there are no mechanical obstructions and you swapped all the boards, the things to look at are cabling. Double check the ribbon cables fo

Universal Advantis Y1 axis error code 10201

Electronics Forum | Tue Jun 27 05:28:32 EDT 2023 | ttheis

We powered up our Advantis machine after leaving off for several months. When we powered it up went to zero it we get an error on the y1 axis during zeroing. Command move home: pattern step 0. The y negative limit is hit during homing, the axis then