Anyone with 2001 era DEK 248 experience?

Electronics Forum | Tue Aug 19 14:24:22 EDT 2008 | shanenaturalpoint

My first problem is that when the unit homes, the print carriage seems to be traveling too far back. After the carriage reaches its mechanical limit, it continues to try and move back, eventually throwing up a print carriage error. Any ideas?

Omniflo 5 high temperature warning

Electronics Forum | Thu Sep 04 02:43:09 EDT 2008 | benefon

Thanks This error only occurred with one oven profile with the reflow zone temperature set at 270�C. Perhaps it really has to do with the exhaust pull as the oven is operating very near its temperature limit with this profile. I will check that. Tha

cp743E

Electronics Forum | Mon Mar 25 14:59:55 EDT 2013 | jimmyboz

Yes, he is correct, it is probably a sensor. That does NOT mean a sensor is bad, just that it has not been activated during a time limit or servo count. Watch what the last 2 or 3 things it does before the error.

Manual SMT equipment

Electronics Forum | Wed Dec 03 06:04:10 EST 2014 | spoiltforchoice

Manual placement aids are often very similar, I would suggest it is quite difficult to tell them all apart. Most of them include some kind of carousel for bins of loose parts and have the option of a few tape "feeders". If you are building small volu

Mydata Centering motor problem

Electronics Forum | Mon Sep 21 00:11:14 EDT 2009 | darrenj

We have a TP9 with a centering motor issue. (TPSYS Ver 2.5.3) The error message F-MOT-SETDYN C/3 Upper endpoint outside limits is shown during C-motor initiation. I've looked in the service program and also the parameters in TPSYS but can find no m

MPM 2000

Electronics Forum | Mon Oct 17 13:02:28 EDT 2016 | tdemon69

i have a MPM2000 now giving me 0 - hardware limit warnings..let me start off by saying that is was giving me x axis limit problems, so i replaced the x card with diff card. set all the switch and jumpers to x card , then i got 0- hardware . so then

Koh Young 3030VAL Failure on Homing

Electronics Forum | Thu Mar 24 23:34:55 EDT 2022 | glasscake

My Koh Young 3030VAL errors on the homing routine. The "DTool" "MCS" gives me an error "Before homing, X-AAxis already checked negative limit..." "Before Hoking, Y Axis already checked negative limit..." "Please turn off the control-power-switch, an

MYData issue

Electronics Forum | Tue Jun 19 11:28:10 EDT 2007 | kpm135

I am fairly new to the MYData machine. The TP11 we have just started generating the following error: W-MIPR-20:System voltage BATTERY measured 14.59V (outside limits). After talking with the operators and reading the manual I believe the problem may

inline AOI (whats the best!)

Electronics Forum | Wed Nov 16 12:01:59 EST 2011 | benreben

Hi, for me the best system AOI is SAKI because is not a head with a FOV but is a scaner. this scaner take the image board in a few seconds. This machine have many algorithm for inspect all errors on a board. But the interface is difficult and the pr

Assembleon Topaz X

Electronics Forum | Sat Oct 06 15:00:42 EDT 2012 | chrisnims

We bought a used 1999 topaz x and are trying to get it up and running. unfortunately we are getting an error: Anyone know where i can get a service manual or having any idea where to look to resolve this problem? "E229" “Nozzle down limit sensor is