Dek Infinity- Automatic Screen Changer does not load the screen in the correct position.

Electronics Forum | Tue Nov 19 12:36:01 EST 2013 | youngbuck

DEK Infinity-Does anyone have any information on why the automatic screen changer would load the same screen in a different position everytime you load and unload? We constantly have to do a search step for the fiducial and most of the time it will e

Speedline MPM UltraPrint 400 Initialization Error

Electronics Forum | Fri Apr 29 15:17:54 EDT 2022 | glasscake

If the machine was working appropriately before the hard drive failure i would lean on the issue being a configuration issue. Lots of machines have options in their software for different sized motors, limit sensors, IO configs, ext. See if you cant

MPM UP2000HiE Hardware Limit Warning - E00938

Electronics Forum | Sat Jan 21 10:28:16 EST 2023 | compit

The so-called "drivers" are used to control each servo - control boards at the back of the machine. There are several (8?). If one is "worn out" and has no strength to move the servo, maybe this is where the error comes from? They can be interchanged

MPM UP2000HiE Hardware Limit Warning - E00938

Electronics Forum | Sat Jan 21 11:39:11 EST 2023 | atpico

Thank you Michal, The MPM error messages are ambiguous to say the least and one axis not zeroing was a possible cause. But I put here what I learned again and again with this machine: when something doesn't work start by checking the fuses, all of

Re: SMD Inspection and Touch-up

Electronics Forum | Mon Jul 26 10:44:08 EDT 1999 | Boca

| There is a practise within the industry of an Inspector inspecting a board, and that same Inspector performing touch-up. My opinion is that the Inspection and Touch-up operations should be separate functions whereby the Inspector is not performing

QP 242

Electronics Forum | Tue Mar 29 04:15:01 EDT 2011 | ravo

Dear All, Thank you so much for your cooperation. Actually am in continous problems with my BGA and can not assemble it using my QP242 till now, I am using the following data : Vision no. : 1 Vision Type: 230 Height: 2.32 Body Size X: 27.00 +-0.

AOI systems

Electronics Forum | Thu Mar 29 08:23:02 EST 2001 | CAL

Some AOI manufacturers require you to put in a GOLD PCB. Gold PCB is a perfectly manufactured board - Correct placements, correct polarity, no solder short, a "GOOD" PCB. With the vision limitations of some AOI equipment components that have variatio

3D Vision vs 2D vision

Electronics Forum | Thu Jul 12 13:37:18 EDT 2001 | markc

I can't comment on the quality of any vendors equipment, but your question is really a "process approach" issue. What do you expect to find with that 3rd dimensional measurement? 2D inspection should detect the majority of your printing errors.

place BGA by FUJI IP3

Electronics Forum | Wed Apr 24 03:24:53 EDT 2002 | Gang shen

today I succeed placing the BGA at the other table(table2), the part data is only changed with "pitch_limit"=50%,lead_check_ area=50%,lead_brightness=0. but when I process vision at the tale1(which equipped the MTU),still failed,the error message is

would like any input on MPM problems

Electronics Forum | Fri Sep 22 08:37:47 EDT 2006 | john

Using MPM UP2000 Hie printer.When give cycle wiper command,After comleting forward stroke machine gives error wiper not parked,press next to continue.If press NEXT VY axis software limit comes and machine give message press NEXT to continue.IF press