Now only days away, National Electronics Week continues to attract widespread support industry-wide. Being held at London’s Earls Court 2 from June 16th – 18th, the show is renowned for its unprecedented scope of coverage. However, as show organiser Claire Jeffreys points out, it is committed to serving the UK's production industries comprehensively.

NEW Events Ltd

Aegis Manufacturing Operations Software Deployed Factory-Wide by Pactron

Industry News | 2012-02-15 21:45:28.0

Pactron has recently purchased an Aegis Manufacturing Operation Software (MOS) system to improve efficiency across their facility. This system comprises Aegis’ iLaunch, iView, iTrac, IQ and XLink software modules.

Aegis Industrial Software Corporation

part x-out from board when exit in mirtec offline pc.

Electronics Forum | Fri Dec 27 07:20:38 EST 2019 | dipak123

We have Mirtec MV-6 OMNI machine. If programer changes in part number ,then that part x-out from it's place.Value of X & Y incresed 10X compare to other parts in ATT.

AXI (X-Ray) skip X-out board

Electronics Forum | Wed Sep 01 02:48:49 EDT 2021 | cmchoue

Hi Experts, I'm looking for how to auto skip the AXI(X-Ray) inspection on X-out board,Did any folks have the experience on this? Looking for your advice. AXI machine,Virtox and Matrix Thank you CM

BGA dropping off the board

Electronics Forum | Thu Feb 14 07:34:10 EST 2008 | jdumont

How many fell off out of your entire lot? What was the soldering quality like on the ones that didn't fall off (xray, visual)? You need to determine if its a random problem or if even the ones that stayed on are barely on and go from there. If the o

Question on how to save the board image along with the results on Mirtec MV-3U after inspection is complete

Electronics Forum | Fri Dec 09 01:05:11 EST 2022 | varun

We have a Mirtec MV-3U AOI machine. Can someone help me to find a way on how to save the image of the board along with the report after the inspection is complete? Currently it only saves the report with the errors showing on the template image which

Question on how to save the board image along with the results on Mirtec MV-3U after inspection is complete

Electronics Forum | Tue Oct 03 18:13:46 EDT 2023 | glasscake

Its ether going to be in the settings before launching the software at the login screen or the settings after launching the softer on the top right. You should see some tab relating to defects. There should be a setting that says something along the

AOI Mirtec make program

Electronics Forum | Thu Aug 18 09:46:40 EDT 2016 | jbuckley

Put anything over one of the fiducials being used in the circuit, and run the board. It will stop, and on the top right a window will pop up. Click "Skip Current Module" and it will X-out that circuit. If you are using the fiducials on the rail, rath

X-Out Board

Electronics Forum | Sun Mar 04 02:21:40 EST 2012 | eadthem

Most PNP machines and AOI machines shuld have a X out feature. For us we use to use whiteout pens to mark the badsense spot. Now atm we use white lables, becuase there is no dry time. The lables have there own issues, They cause overpasteing issues

X outs

Electronics Forum | Thu Jul 25 21:41:03 EDT 2002 | davef

1.0 X-OUT POLICY 1.1 Each Panel not to contain in excess of X% X'd-Out boards. 1.2 Each X-Out board to be marked in a manner so that Pick & Place equipment will not attempt to insert those boards X'd-Out such as fiducial reference hole for paneliz