Industry Directory | Consultant / Service Provider / Manufacturer
Eureka Dry Tech's IPC/JEDEC J-Std-033c Ultra Low Humidity Dry Cabinets provides moisture/humidity controlled storage of MSD,PCB, IC packages. Drying technology trusted by millions in replacing baking, nitrogen & desiccant packs.
Industry News | 2011-12-30 23:20:54.0
SMART Group, Europe’s largest technical trade association focusing on surface mount and related technologies, announces that it will host a workshop titled Handling Moisture-Sensitive Components & PCBs Without Failure on Wednesday, January 25, 2012 at the Stoke Mandeville Stadium in Aylesbury, Buckinghamshire, UK.
New Equipment | Board Handling - Storage
Eureka SDC-101 Fast Super Dryer Ultra Low Humidity Dry Cabinet Specs: http://eurekadrytech.com/fast-super-dryer/sdc-101 Anti-static Glass, Anti-static Paint on Body and Shelves, Anti-static Stands, 1 M ω Ground Wire Model: SDC-101 Fast Super Drye
Technical Library | 2021-11-26 14:34:07.0
The use of desiccant bags filled with Silica Sand and or Clay beads used in conjunction with a Moisture Barrier Bag to control moisture for storage of printed circuit boards has long been an accepted practice and standard from both JEDEC and IPC organizations. Additionally, the use heated ovens for baking off moisture using the evaporation process has also been a long#2;standing practice from these organizations. This paper on alternative drying methods will be accompanied by completed independent, unbiased tests conducted by Vinny Nguyen, an engineering student (now graduated) from San Jose State University. The accompanied paper will examine the performance levels of different technologies of desiccant bags to control moisture in enclosed spaces. The tests and equipment set were reviewed by an engineer and consultant to the Lockheed Martin Aerospace Division and the IPC - TM-650 2.6.28 test method was review by engineer from pSemi. The tests were designed to mimic performance tests outlined in Mil Spec 3464, which both IPC and JEDEC have adopted for their respective standards. The test examined variables including absorption capacity rates, weight gain and release of moisture back into the enclosed area. The presentation will also address and highlight: • Similarities of PCBs and Heavy Equipment as it applies to Inspections, Causes of Failure, Types of Corrosion and Moisture Collection Points. • Performance Attributes of Different Desiccant Technologies as it applies to shape, texture, change outs, labeling and regeneration. • Venn Diagram of Electromechanical Failure with the circles 1. Current 2. Contamination 3. Humidity Presentation Available
New Equipment | Board Handling - Storage
Eureka SDC-2001 Fast Super Dryer Ultra Low Humidity Dry Cabinet Specs: http://eurekadrytech.com/fast-super-dryer/sdc-2001 Model: Eureka SDC-2001 Fast Super Dryer Capacity: 1314 Liters Humidity Range: LESS THAN 10% Recovery Time: Recovers to ≤ 10% R
Technical Library | 2024-09-02 18:48:58.0
The conversion to higher temperature "Lead Free" assembly reflow conditions has created an increased awareness that entrapped or absorbed moisture is a frequent root cause of thermally induced delamination at assembly reflow. There are two connected failure modes from entrapped moisture; incomplete resin cross-linking resulting in premature resin decomposition and also severe Z axis expansion from "explosive vaporization of the entrapped moisture at elevated temperatures at assembly reflow". Ultimately, both result in delamination failure. Other papers have shown the negative effects of entrapped moisture before lamination including delamination, red color, reduced thermal reliability and increased high speed signal loss. In this paper, various materials were tested for moisture sensitivity during lamination. Tests were performed at varying lamination conditions including a pre-vacuum step and "kiss" step. Pressure and cure temperature parameters were evaluated for minimizing or eliminating the effect of trapped moisture. Also included are the results of inner layer moisture removal baking conditions and their effect on peel strength and thermal reliability.
New Equipment | Board Handling - Storage
SDC-1001 Fast Super Dryer Ultra Low Humidity Dry Cabinet Specs: Model: SDC-1001 Fast Super Dryer Capacity: 657 Liters Humidity Range: LESS THAN 10% Recovery Time: Recovers to ≤ 10% RH within 30 minutes after accessing door for 30 seconds or less. Ex
Industry Directory | Manufacturer
Dry cabinet is used to store moisture-sensitive electronic(such as pcb,ic,chips,crystals,wafers,etc.)under low humidity to avoid moisture-related defects.we have 15 years'experience with CE certified.
Industry Directory | Manufacturer
Dry cabinet is used to store moisture-sensitive electronic(such as pcb,ic,chips,crystals,wafers,etc.)under low humidity to avoid moisture-related defects.we have 15 years'experience with CE certified.
Industry News | 2017-10-23 05:53:04.0
Selected Bob Willis webinars are released for the end of 2017 and the beginning of 2018. Book online to secure your place or for your team training. If the date or time does not suit your schedule its also possible to arrange online training at a time and date that is better for you http://www.bobwillis.co.uk