Full Site - : motor mydata (Page 11 of 23)

Mydata ywagon

Electronics Forum | Mon Jul 16 10:45:47 EDT 2012 | cyber_wolf

The trandsducer on the motor.

MYDATA My9 Theta error

Electronics Forum | Tue Dec 18 21:47:14 EST 2012 | jaimebc

So just to update and close this thread, it was the ZFIB board ( the one mounted on top of the theta motor) that was causing the theta motor to error out) Problem fixed. $ 30 dls or so from MYDATA. Hope this helps some one down the road.

MYDATA My9 Theta error

Electronics Forum | Thu Nov 15 23:45:53 EST 2012 | jaimebc

robgd3, The Z motor can be purchased separately, however, the theta motor can't. You need to buy the whole midas head. I didn't get as far as dissembling the theta motor casing to get to the theta motor. That was my worse case scenario. We ran thou

F-MOT-MSETDYN Theta/12: No axis movement detected by transducer

Electronics Forum | Thu Feb 06 20:23:35 EST 2020 | bilalfarooqi

Hey everyone, We use a MyData MY12 machine and we are experiencing a problem with the Midas head. I recently replaced a torn vacuum tube that goes on the zfib card. The machine worked perfectly for a day and a half but now MY12 has completely stoppe

MYDATA TP11 - Motor Controller M error

Electronics Forum | Fri Jun 03 11:13:28 EDT 2011 | jeremymc

I've been running a MYDATA TP11 for over a year now and yesterday when I turned it on I was given an error that I have never seen before. It had been a week since the last time I had used the machine and when it was turned on it told me that there

Mydata TP9 UFP problems

Electronics Forum | Sat Jun 25 01:05:13 EDT 2005 | pci

check the X axis belt , guides and Z axis motor

MYDATA M12

Electronics Forum | Fri Jul 10 18:47:27 EDT 2015 | alphatronique

make sure noting stock in the X ,and motor brake work usually machine supply 24V to motor brake wire for release brake then move until hit the end stopper for init motor if brake keep on that will the error message i got it often on the Z cause

Mydata TP9-2U error ?

Electronics Forum | Thu Aug 22 11:30:47 EDT 2019 | rgduval

It's a motor controller card error. I'm not completely sure, but, it seems like something in the x. Swap MOT1 with MOT2 or 3, and see if the error moves. If it does, you have a bad MOT card. If it doesn't, you have something going on with a motor

MyData My9 "no z indicator value at all"

Electronics Forum | Mon May 09 19:24:53 EDT 2022 | rgduval

It's been a minute...but, does the My9 still have MOT boards in the computer cage? If so, swap the MOTz with the MOTx or MOTy, and see if the problem moves. If so, replace the motor controller board. If not, +1 on the encoder or Z-motor. Check fo

MY 9 error F-MOT-MSETDYN X/163

Electronics Forum | Fri Apr 21 14:22:45 EDT 2023 | padawanlinuxero

Do all of the above (robgd3) In my case the problem was a motor inside the moving head started to give up so it kinda miss the synchro with the other motor on the outside, and in my case we bought the new motor but it took several day to fix with the


motor mydata searches for Companies, Equipment, Machines, Suppliers & Information

Global manufacturing solutions provider

Stencil Printing 101 Training Course
Blackfox IPC Training & Certification

High Precision Fluid Dispensers
Equipment Auction Automotive Electronics Supplier - Closure of Tier-One SMT Dvision: (10) ASM & Universal SMT Lines & Feeders Equipment as-new-as 2019! Dek | Koh Young | Speedline | Vitronics | Viscom