Full Site - : motor mydata (Page 14 of 19)

Mydata TP-11 Small X not working

Electronics Forum | Wed Apr 15 12:57:37 EDT 2009 | bk

I'm not sure if you fixed your problem yet or not but i'll give you some insight on your problem. The x wagon motor doesn't move cause of the voltage it actually moves when there's current applied to it. The voltage dictates the direction the motor m

MYDATA My9 Theta error

Electronics Forum | Tue Nov 13 12:02:54 EST 2012 | jaimebc

I'll try swaping cards and see if the problem follows the card. So far, my guess would be the motor going bad. I did change the brushes, X wagon cables and every cable that goes to the midas unit. But that didn't fix it. The problem is that to replac

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Fri Nov 22 10:24:28 EST 2019 | rgduval

When you swapped the MOT card, did the proble move to another axis? I'm guessing no, but, wanted to clarify. If the problem did not move, you either have an x-motor problem, x-motor counter problem, or x-transducer problem as noted. Or, a cable pr

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Wed Mar 04 12:51:41 EST 2020 | bk

That error means your hydra z did not reach it's specified position. With the machine on you should be able to manually push the hydra down and let it come back up. Make sure it isn't being held up or hitting anything as goes down. Lots of times a pa

My Data

Electronics Forum | Fri Dec 28 13:11:13 EST 2001 | cyber_wolf

Chris, I have worked with all kinds of Mydata's TP9,TP11,MY series machine for years. I have ran them, programmed them,and had just about every nut, bolt,motor, and circuit board out of them at one time or another.I have also written specialized mai

Mydata A12 tool tip damage

Electronics Forum | Wed Jul 18 06:47:38 EDT 2007 | cyber_wolf

I was asking if it was a TP9 2U...... If you have a UFP machine then you are in luck. It is most likely the small X-motor. You can test it in the service program. Does the X-axis bounce when you are trimming magazines and stepping through placement

Mydata TP11-UFP won't initialize

Electronics Forum | Tue Jan 04 13:00:07 EST 2011 | bk

The only x fan i can think of would be the x belt motor fan which is on the back of the black box sticking out of the back of the machine. If it's a heat issue then first thing to do is replace the 2 filters behind the 2 vented covers located on the

transducers out of sync error, Mydata TP-11

Electronics Forum | Tue Feb 28 07:31:40 EST 2012 | bk

I'm assuming it's your x wagon tranducers that are out of synch. So the first place to start is look at your couplings on both x motors and make sure one of them isn't broken or starting to break. After that i would try swapping out your x board with

Hardware initiation failiure on start up (mydata TP11 )

Electronics Forum | Tue Oct 22 21:24:02 EDT 2019 | richgreen01

Hi All I have the above machine and every day on start up i get the failed to initiate hardware message.I have been getting around this by re initiating the motor controllers and it is good to go after this.Does anyone know the causes of the initiat

MYDATA HYDRA Z/156 error on Hardware Intialization.

Electronics Forum | Fri Mar 06 14:33:53 EST 2020 | bk

Another thing you can check is where the bar comes down off of the hydra z motor there is a little bearing you can see from the front make sure that bearing is turning even oil it up a little. You can also adjust the tension by loosening the tiny set


motor mydata searches for Companies, Equipment, Machines, Suppliers & Information

SMTAI 2024 - SMTA International

World's Best Reflow Oven Customizable for Unique Applications
Sell Used SMT & Test Equipment

Training online, at your facility, or at one of our worldwide training centers"
IPC Training & Certification - Blackfox

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
Voidless Reflow Soldering

Component Placement 101 Training Course
Hot selling SMT spare parts and professional SMT machine solutions

Internet marketing services for manufacturing companies