mpm up2000 z axis hardware limit

Electronics Forum | Fri Oct 04 13:47:25 EDT 2019 | compit

I had as I placed the supports at the back - when lifting Z touched the rear rail - check.

mpm up2000 z axis hardware limit

Electronics Forum | Wed Dec 04 08:02:02 EST 2019 | proceng1

Contact George Castonguay at PPM. He is a Jedi when it comes to these machines. In fact, since you just got it, a good investment would be to have George come in and go through the machine and get it calibrated. 603-895-5112 They also sell parts

Tactile Hardware limit MPM Ultraprint 2000

Electronics Forum | Tue Aug 04 09:02:34 EDT 2009 | kpm135

We replaced the tactile sensor's linear actuator on a MPM Ultraprint 2000 HiE. Now we are getting a Tactile Hardware limit error every time we try to find the stencil height. I was hoping some one could explain why we're getting this error and any i

Tactile Hardware limit MPM Ultraprint 2000

Electronics Forum | Tue Aug 04 13:44:05 EDT 2009 | swag

Check your DIP switch settings on new driver. Not sure about calibration. Try QMPM for password.

Tactile Hardware limit MPM Ultraprint 2000

Electronics Forum | Tue Aug 04 14:43:12 EDT 2009 | kpm135

Thank you very much SWAG that password did the trick. Got us into the calibration menu and we were able to calibrate the z-axis and snugger height and got it to work. Thanks again

Tactile Hardware limit MPM Ultraprint 2000

Electronics Forum | Tue Aug 04 10:19:38 EDT 2009 | swag

Here's a few ideas: If it has one, make sure the flexible coupler set screws are tight. Replace the tactile switch (often these appear to work fine in I/O but do not work properly in production). Clean and oil the tactile plunger if it has one. M

Tactile Hardware limit MPM Ultraprint 2000

Electronics Forum | Tue Aug 04 10:43:48 EDT 2009 | kpm135

Thanks for the suggestions! It ended up being that a wire on the amplifier card in the lower drawer came loose and was making intermittent contact. Tightened all the wires down and the problem has gone away. Now we have a new problem. We had to repla

MPM 2000

Electronics Forum | Mon Oct 17 13:02:28 EDT 2016 | tdemon69

i have a MPM2000 now giving me 0 - hardware limit warnings..let me start off by saying that is was giving me x axis limit problems, so i replaced the x card with diff card. set all the switch and jumpers to x card , then i got 0- hardware . so then

MPM Ultraprint 2000

Electronics Forum | Tue Mar 28 19:28:54 EDT 2017 | aemery

Giao, These style of MPM's use stepper motors, but no feedback like an encoder or a resolver. In other words all axis positions are assumed after "Reset" of the machine. Because of this style of drive system there is the potential for the vision ga

MPM 2000

Electronics Forum | Tue Nov 08 10:52:29 EST 2016 | aemery

Tom, Hardware limit means the machine thinks it is at the limit sensor or a particular axis timed out before it got to the home sensor during the reset sequence. Go to your O/I map and see if any of the axis limit sensors are lit. You could have a


mpm ultraprint 2000 hardware limit warning searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

Software for SMT placement & AOI - Free Download.
Blackfox IPC Training & Certification

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
Online Equipment Auction of Altronic: Small-Batch Surface Mount & Assembly Facility

High Throughput Reflow Oven
PCB Handling Machine with CE

World's Best Reflow Oven Customizable for Unique Applications