Electronics Forum | Thu Jan 19 18:11:45 EST 2023 | atpico
My UP2000 HiE Printer on Power-ON during initial Reset will show this error and reset will abort with no way to continue. E00938 10 - HARDWARE LIMIT WARNING In Input/Output Screen all Sensors are in normal situation and will react normally when t
Electronics Forum | Wed Aug 05 14:20:21 EDT 2009 | jorge_quijano
Hello there, I'm having some problems w/MPM up2000, Vision Y axis software limit error, when I tried to create a new program, appears the "Value out of range for VY BSS POS, spec 0.00 min -26.5, read 8.45" message. Any idea of how to correct this pro
Electronics Forum | Sat Jan 21 11:39:11 EST 2023 | atpico
Thank you Michal, The MPM error messages are ambiguous to say the least and one axis not zeroing was a possible cause. But I put here what I learned again and again with this machine: when something doesn't work start by checking the fuses, all of
Electronics Forum | Thu Oct 21 11:15:00 EDT 2010 | jorge_quijano
Do you know in which axis the problem occurs? usually when "hardware limit error" shows is because one of the axis touches the sensor of the limit, this is to prevent the mechanism hit something, If you machine is used, you can check if there is a mi