Full Site - : mpm z axis limit switches (Page 40 of 42)

Universal instruments corporation - TAB Bonder - Z Axis DAC limit error during Absolute command

Electronics Forum | Tue Oct 01 18:44:24 EDT 2013 | richardconnell

Hi, I have limited capability on the Z axis. The axis will home to the mechanical switch limit and then drop to a point which I asssume to be the fiorst zero point below the mechanical switch limit. Then it gives the error. There is power to the mo

MPM UP3000 Question

Electronics Forum | Fri Aug 11 11:18:20 EDT 2006 | chrisgriffin

I got a 3000 that is acting crazy. After a print, the board is unclamped and the Z-axis lowers. It continues to lower until it trips the limit switch. It is suppposed to move in the Y-axis to line up with the tracks while lowering in the Z-axis.

MPM Ultrapint series 2000

Electronics Forum | Mon Jun 19 21:25:47 EDT 2006 | Chris

Try raising the table in Calibrate mode. Sensor or Tactile connector could be contacting the underside of the rails and overloading the axis. Check for 24V on the Z-axis brake. Check the fuse(F5) and voltage to the driver. Check DIP switch settin

MPM UP2000HiE Hardware Limit Warning - E00938

Electronics Forum | Sat Jan 21 11:39:11 EST 2023 | atpico

Thank you Michal, The MPM error messages are ambiguous to say the least and one axis not zeroing was a possible cause. But I put here what I learned again and again with this machine: when something doesn't work start by checking the fuses, all of

MPM UP2000 elite calibration

Electronics Forum | Fri Oct 04 13:14:13 EDT 2019 | ddfreeze

I need to access the calibration menu, does anyone have a password for it? having issues with the z axis hardware limit. doesn't appear the card is bad. board raises to camera and goes back down???

Need help for contact 3AVX

Electronics Forum | Tue Nov 01 09:36:41 EDT 2011 | emeto

THe question is - does that happen on all of your programs or just in one program? If it is just this particular board, it might be some softwaRE limit issue. If it happens on more programs it is a hardware issue and it could be one of the following:

MPM 2000

Electronics Forum | Mon Oct 17 13:02:28 EDT 2016 | tdemon69

i have a MPM2000 now giving me 0 - hardware limit warnings..let me start off by saying that is was giving me x axis limit problems, so i replaced the x card with diff card. set all the switch and jumpers to x card , then i got 0- hardware . so then

SPM AV Different Problem

Electronics Forum | Wed Jun 08 13:16:02 EDT 2005 | cyber_wolf

It sounds to me like it may be your squeegee Z motion controller card. The SQUEEGEE Z motion controller card is interchangeable with some of the other motion cards in the back of the machine.(NOT ALL OF THEM) Make sure you look at the power ratings a

MPM UP2000HiE Hardware Limit Warning - E00938

Electronics Forum | Fri May 05 21:10:41 EDT 2023 | zsoden

Hi ELC, I'm curious about your comment of calibrating the Z axis. Our UP2000 has been moved around a few times and we've never done this nor noticed a need to. Could you please share some more information and even perhaps the calibration procedure?

MPM UP2000 Hardware Limit

Electronics Forum | Wed Feb 20 15:21:56 EST 2013 | rmitchell

Hi, hopefully I am too late, it is fixed and you are up and running. Have you tried MPM support on the phone? We have 2 older MPM's and the blow the driver modules in the bottom drawer on the back of the machine. There are different drivers for dif