Electronics Forum | Mon Sep 04 10:33:07 EDT 2017 | sarason
http://www.rohrhofer.org/r-tec/ which is more thorough than mine regards sarason
Electronics Forum | Fri Aug 12 20:09:41 EDT 2005 | dorklover664
First off I would like to say it's good to be back. I haven't been working production and I'm really glad to be back. Next... I am looking for either a used MyData flex or 12/16 magazine. Cheap is the key (new company has less then 50 employees)! We
Electronics Forum | Fri Dec 28 13:11:13 EST 2001 | cyber_wolf
Chris, I have worked with all kinds of Mydata's TP9,TP11,MY series machine for years. I have ran them, programmed them,and had just about every nut, bolt,motor, and circuit board out of them at one time or another.I have also written specialized mai
Electronics Forum | Tue Jul 18 15:16:40 EDT 2017 | robertbronx
Showing on screen this message: MIPR2: Fatal Error. Reloading Motor Controller M First time I connect and only have this message on screen. The manual only says; 1) SOFTWARE PROBLEM IN THE MOT-M SERVO PROGRAM. 2) THE MOT-M OR MI board is broken. Plea
Electronics Forum | Fri Jul 21 09:45:35 EDT 2017 | robertbronx
Hi, Dave Good morning, thank you for reply and the info. I find out the problem was an UNCONNECTED PLUG on the Power Supply unit. Which was probably caused when it was packed and shipped. Again, Thank you!! Regards
Electronics Forum | Mon May 09 19:00:47 EDT 2022 | SMTA-64387687
Z-force sensor is a tool travel indicator. It has nothing to do with Z travel. Does the Midas head move at all, during initiation? It sounds to me like a Z motor/encoder problem. Is the Midas head ribbon cable plugged in?
Electronics Forum | Mon May 09 19:27:19 EDT 2022 | mikevb
Thanks for the response. Yes, the z motor initializes in the service program just fine. It moves and reads a position. Also in the service program, I try to test the z force sensor and it gives me the same error - no z indicator at all. All cables ar
Electronics Forum | Wed Oct 24 11:10:55 EDT 2007 | dyoungquist
We are running an upgraded, refurbished MyData TP9 machine in our high mix, low volume production. With those improvements it does okay on the 0402s. The TP platform is no longer in production but they are still providing good support for machines
Electronics Forum | Sun Nov 04 01:11:19 EST 2007 | daxman
If we're comparing a TP9 or a MY9 to anything FUJI, I think the IP3 has it beat by a long shot. You can get a used IP3 with an MTU for under 35k. The only downside is that you require a programming interface with Fuji and it's built into the MyData.
Electronics Forum | Thu Apr 07 11:39:48 EDT 2011 | remullis
My oven profile is 155,160,165,180,220,245,255,227 Cooling Zone 132/92. This is a 8 zone CV820 Technical Devices oven. My assy profile using Datapaq Q18 - Base on one probe feedback - Positive slope (7.09), Pos Slope Time (.45), Rise Time (1.17), Me