Electronics Forum | Thu Dec 22 15:11:40 EST 2022 | jbrochecouste
hello, I am looking for information on the following error message: F-MOT-MSETDYN HYDRA Z/156 / TIMEOUT... on a MY12, tell me your experience until the problem is solved
Electronics Forum | Thu Nov 24 16:53:03 EST 2011 | dontfeedphils
Oh wow, I suppose that would fix it huh? That's too bad that the whole unit had to be replaced, but look on the bright side, you should have a decent amount of spare hydra parts now right? haha
Electronics Forum | Mon Nov 21 21:46:49 EST 2011 | supse
Thanks Phil But the belt and spring has been changed recently. Unfortunatly we couldn't wait any longer for a solution, so we had to go for a change of the hydra-unit. This seems to have solved the matter, but I had hoped for a less expensive solutio
Electronics Forum | Tue Nov 15 23:03:07 EST 2011 | supse
Hi I have a problem with one of our MY12 machines, the machine stops very often (approx. 10-20 times a day) writing the following error message : f-mot-msetdyn hydra theta/205(f-hrdw-3). We then have to reinitialize the machine to continue productio
Electronics Forum | Mon Dec 26 18:02:37 EST 2022 | rgduval
So, your Hydra Z message timed out... A couple of potential causes: 1. Hydra MOT card failure 2. Hydra z-motor failure 3. Hydra z-motor encoder failure 4. Hydra z-lock failure 5. Disconnected cable 6. X-wagon cable Start by booting into service mod
Electronics Forum | Tue Dec 06 18:35:21 EST 2022 | cyber_wolf
Sounds like the Hydra is disabled in settings. One of the Micronic experts will have to tell you where that is.. My last Hydra was a MY12 many years ago.
Electronics Forum | Wed Nov 16 18:20:39 EST 2011 | dontfeedphils
According to the message guide it just says that it's a error telling you to initiate the Hydra Theta axis. I suppose the encoder for the hydra theta motor could be losing count and causing it to need to be re-initiated, or it could be something to
Electronics Forum | Thu Feb 16 05:59:38 EST 2006 | jobbie
Hi everyone, New to the forum and have a question. How many cph are others getting? We are small sub-contract firm and are running Mydata my12 with hydra, but not agilis feeders. We tend to do small batches (upto 100 circuits), high mix from 0402 to
Electronics Forum | Thu Dec 06 10:10:52 EST 2001 | edmentzer
We have a MY12 with the Hydra head, its a great machine for us. We had a MultiTroniKs before. The MYDATA is easy to program, easy to use, is very accurate, is easy to change from job to job. In the 18 months we have had the machine the only proble
Electronics Forum | Wed May 22 12:51:15 EDT 2002 | cyber_wolf
I cannot tell you about the MY-9's , but we have had a MY-12 machine w/i hydra for about two years. We run it pretty steadily on three shifts including a weekend shift. It is a very reliable machine, BUT it is very picky about maintenace. You need to