Full Site - : mydata f-mot-msetdyn (Page 2 of 2)

Mydata MY12 Hydra Theta error

Electronics Forum | Tue Nov 15 23:03:07 EST 2011 | supse

Hi I have a problem with one of our MY12 machines, the machine stops very often (approx. 10-20 times a day) writing the following error message : f-mot-msetdyn hydra theta/205(f-hrdw-3). We then have to reinitialize the machine to continue productio

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Fri Nov 22 00:09:29 EST 2019 | mk15

I am looking for some help for where to look to fix this MY15E problem. 1. after hardware initiation appear - F-MOT-MOVE X/250: Motor speed out of control (photo1). 2. in service mode when x motor initiate appear - F-MOT-MSETDYN X/12: No axis movemen

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:22:53 EDT 2014 | rgduval

Hi, Rebecca, Hmm...two x motors? I'm a couple of years removed from MyData's, but, I don't remember two x-motors. Might be something in the My12's that I didn't see in my older My9 (and certainly not in my TP9). As to the small board...unfortun

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 16:36:29 EDT 2014 | chemers

Thanks for the response, Rob. I tried the MOT cards and the problem did not move. I swapped the MOTY with the MOTX, but the MOTX had a small board attached to it that I moved to the MOTY that I tried. Do you know if there is a way to test that small

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:33:32 EDT 2014 | cflames17

It could very well be the Safety Relay located inside the ELMO PSU (Bottom left in computer cabinet). I just had the same problems on 2 MY9's within 2 months apart. the Part cost around $700.00 from Mydata (Now Mycronic). These fail commonly with old

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 09:40:14 EDT 2014 | rgduval

I'm surprised MyData is pushing the service call. They're usually pretty good at walking you through some troubleshooting steps before going straight to the service call. So, the failure sounds like an encoder failure; the encoders are attached to

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 03:33:42 EST 2014 | hans88

hello people, we have a my12 wich has a problem it gives the following error during hardware initialization: F-MOT-MSETDYN Y/1236 :Motor amplifier channel a error. after this error it says hardware initialization failed. this prevents us of using