Electronics Forum | Thu Jul 18 00:08:31 EDT 2019 | mk15
hank you for the tips. MOT boards have already changed. The sensor on the conveyor responds. In service mode, the WIDTH MOTOR - OK, HOLD MOTOR - OK, SET CONVEYOR - OK, only error TRANSPORT - F-MOT-MSETDYN conveyor transport / 1250: amplifier DC-link
Electronics Forum | Thu Aug 14 12:57:45 EDT 2014 | rgeary
Does anyone know what the following error indicates on a MyData My12 running 2.9.2. "F-MOT-MSETDYN C/156"?
Electronics Forum | Wed Jul 17 17:56:38 EDT 2019 | rgduval
Check the MOT board. You can usually swap out the individual MOT boards, and see if the problem moves. If it does, you can isolate which board has gone bad. You can also check the encoder on the conveyor, to make sure that is still working correct
Electronics Forum | Thu Mar 23 13:36:30 EDT 2023 | tomdegas
Running a Mydata MY 9 and trying to Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command argument. It seems to be related to the x drive. I've check all the connections on
Electronics Forum | Wed Sep 03 15:18:12 EDT 2014 | chemers
I am looking for some help for where to look to fix this MY12 problem. We started the machine after the weekend and this error code comes up during initialization. F-MOT-MSETDYN X/12: Position counter dead MyData tells us our only option is to have
Electronics Forum | Fri Sep 05 09:42:41 EDT 2014 | cflames17
If you call service they can also walk you through the motor test. Ask for Glen. Al no longer works for MYDATA.
Electronics Forum | Fri May 24 11:34:08 EDT 2019 | jstebbs89
Running a Mydata 15E and in the middle of a board the machine will freeze. Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command arguement I've check all the connections on t
Electronics Forum | Thu Oct 11 00:11:49 EDT 2018 | mk15
I am looking for some help for where to look to fix this MY15E problem. We started the machine after the weekend and this error code comes. F-MOT-MSETDYN z/3: Upper end point outside limit. Any suggestions? Thanks
Electronics Forum | Fri Apr 21 14:22:45 EDT 2023 | padawanlinuxero
Do all of the above (robgd3) In my case the problem was a motor inside the moving head started to give up so it kinda miss the synchro with the other motor on the outside, and in my case we bought the new motor but it took several day to fix with the
Electronics Forum | Thu Feb 06 20:23:35 EST 2020 | bilalfarooqi
Hey everyone, We use a MyData MY12 machine and we are experiencing a problem with the Midas head. I recently replaced a torn vacuum tube that goes on the zfib card. The machine worked perfectly for a day and a half but now MY12 has completely stoppe