MYDATA MY15E:F-MOT-MSETDYN conveyor transport/1250: amplifier DC-link too high

Electronics Forum | Thu Jul 18 00:08:31 EDT 2019 | mk15

hank you for the tips. MOT boards have already changed. The sensor on the conveyor responds. In service mode, the WIDTH MOTOR - OK, HOLD MOTOR - OK, SET CONVEYOR - OK, only error TRANSPORT - F-MOT-MSETDYN conveyor transport / 1250: amplifier DC-link

MyData error

Electronics Forum | Thu Aug 14 12:57:45 EDT 2014 | rgeary

Does anyone know what the following error indicates on a MyData My12 running 2.9.2. "F-MOT-MSETDYN C/156"?

MYDATA MY15E:F-MOT-MSETDYN conveyor transport/1250: amplifier DC-link too high

Electronics Forum | Wed Jul 17 17:56:38 EDT 2019 | rgduval

Check the MOT board. You can usually swap out the individual MOT boards, and see if the problem moves. If it does, you can isolate which board has gone bad. You can also check the encoder on the conveyor, to make sure that is still working correct

MY 9 error F-MOT-MSETDYN X/163

Electronics Forum | Thu Mar 23 13:36:30 EDT 2023 | tomdegas

Running a Mydata MY 9 and trying to Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command argument. It seems to be related to the x drive. I've check all the connections on

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Wed Sep 03 15:18:12 EDT 2014 | chemers

I am looking for some help for where to look to fix this MY12 problem. We started the machine after the weekend and this error code comes up during initialization. F-MOT-MSETDYN X/12: Position counter dead MyData tells us our only option is to have

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:42:41 EDT 2014 | cflames17

If you call service they can also walk you through the motor test. Ask for Glen. Al no longer works for MYDATA.

MYdata 15E F-Mot error

Electronics Forum | Fri May 24 11:34:08 EDT 2019 | jstebbs89

Running a Mydata 15E and in the middle of a board the machine will freeze. Restart the machine and try to initiate the hardware, get an error message of F-MOT-MSETDYN X/163: Illegal value of DSP command arguement I've check all the connections on t

MYDATA MY15E F-MOT-SETDYN Z/3: Upper end point outside limit

Electronics Forum | Thu Oct 11 00:11:49 EDT 2018 | mk15

I am looking for some help for where to look to fix this MY15E problem. We started the machine after the weekend and this error code comes. F-MOT-MSETDYN z/3: Upper end point outside limit. Any suggestions? Thanks

MY 9 error F-MOT-MSETDYN X/163

Electronics Forum | Fri Apr 21 14:22:45 EDT 2023 | padawanlinuxero

Do all of the above (robgd3) In my case the problem was a motor inside the moving head started to give up so it kinda miss the synchro with the other motor on the outside, and in my case we bought the new motor but it took several day to fix with the

F-MOT-MSETDYN Theta/12: No axis movement detected by transducer

Electronics Forum | Thu Feb 06 20:23:35 EST 2020 | bilalfarooqi

Hey everyone, We use a MyData MY12 machine and we are experiencing a problem with the Midas head. I recently replaced a torn vacuum tube that goes on the zfib card. The machine worked perfectly for a day and a half but now MY12 has completely stoppe


mydata f-mot-msetdyn searches for Companies, Equipment, Machines, Suppliers & Information

PCB Handling with CE

High Throughput Reflow Oven
Solder Paste Dispensing

Easily dispense fine pitch components with ±25µm positioning accuracy.
SMT feeders

Component Placement 101 Training Course
SMT feeders

Software for SMT placement & AOI - Free Download.
Equipment Auction Automotive Electronics Supplier - Closure of Tier-One SMT Dvision: (10) ASM & Universal SMT Lines & Feeders Equipment as-new-as 2019! Dek | Koh Young | Speedline | Vitronics | Viscom

Best Reflow Oven