Full Site - : mydata motor (Page 5 of 19)

mydata 19 error

Electronics Forum | Thu Feb 13 09:52:03 EST 2014 | rgduval

Start by getting into the maintenance menu, and manually installing the Servo program for all MOTs. If they install fine, you can check the Z-motor while you're in the maintenance menus. Make sure that the z-locks are unlocked before checking the

mydata 19 error

Electronics Forum | Thu Feb 20 13:16:15 EST 2014 | rgduval

Hi, Brendan, It sure sounds like it to me. But, with the Z axis, there could be one other thing to check. On my old TP, there were z-locks...two pistons that pointed sideways around the head travel. Initializing the z-motors did not move the z-

mydata 19 error

Electronics Forum | Thu Feb 20 13:25:18 EST 2014 | brendansales

Dear Rob, Thank you for your quick response! There were Z locks on the Midas head area, 2 little solenoids like you mentioned. Previously I had the first error code (F-AXIS-C/9) and after fiddling around, randomly manual unlock the Z locks it came

mydata 19 error

Electronics Forum | Thu Feb 20 13:56:18 EST 2014 | rgduval

Brendan, Unfortunately, I no longer have MYData equipment in my shop (I moved to a new company), so, I can't help with finding part numbers. I do know that you can buy the motor/counter units separately on the open market..and, I think you can buy

Mydata Centering motor problem

Electronics Forum | Mon Sep 21 03:52:17 EDT 2009 | darrenj

Found the problem. A small part had previously fallen off the nozzle, and ended up behind the left centering jaw preventing the jaw from opening up fully. Cheers Darren

Mydata Centering motor problem

Electronics Forum | Mon Sep 21 00:11:14 EDT 2009 | darrenj

We have a TP9 with a centering motor issue. (TPSYS Ver 2.5.3) The error message F-MOT-SETDYN C/3 Upper endpoint outside limits is shown during C-motor initiation. I've looked in the service program and also the parameters in TPSYS but can find no m

Mydata Lift motor 2 amplifier error

Electronics Forum | Thu Oct 15 10:21:30 EDT 2015 | azdback

troubleshooting a table lift error on MY12. Error code: F-MOT_Releaseboard conveyor lift/1304. Basically, the table got stuck on the up position. Also bench tested both lift motors and they are ok.Rotated the lift motors manually to test the encoder

Mydata My9 X MOT motor timeout

Electronics Forum | Wed Jun 15 19:46:15 EDT 2022 | mikevb

Hey All. I figured it out. It turns out that the problem was simply a loose coupler on the x wagon motor transducer. I had only checked one screw in the past but the other screw was apparently loose as well.

Mydata My9 X MOT motor timeout

Electronics Forum | Sun Jun 12 01:44:59 EDT 2022 | mikevb

I forgot to mention that I've measured and adjusted the cog play on the x axis and so it is within range, if that applies.

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 15:59:25 EDT 2022 | mikevb

Thanks! I just needed a response like that. I will do all that, and if it's still an issue, I'll change the x wagon encoder right? There are three encoders on the x wagon though? The white one on the x carriage, the white one on the x belt drive mo


mydata motor searches for Companies, Equipment, Machines, Suppliers & Information

IPC Training & Certification - Blackfox

Training online, at your facility, or at one of our worldwide training centers"
Thermal Interface Material Dispensing

High Throughput Reflow Oven
Void Free Reflow Soldering

World's Best Reflow Oven Customizable for Unique Applications
Pillarhouse USA for Selective Soldering Needs

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...