Full Site - : mydata motor (Page 6 of 19)

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 15:02:13 EDT 2022 | glasscake

Start with fundamentals: Disconnect, clean and reconnect all inner connections, bulk heads, ext. Disconnect, reconnect all connections at the controller. Check wiring harness for conductivity. Clean everything appropriately, lube ways, balls screws

Mydata My9 X MOT motor timeout

Electronics Forum | Tue Jun 14 16:23:22 EDT 2022 | glasscake

Cant put a finger on it being an encoder that was just a single possibility. You can always hook up a scope to the encoder and see if they are working appropriately. I would look through the machine's utilities and see if there is some debug or more

Mydata My9 X MOT motor timeout

Electronics Forum | Sun Jun 12 01:38:47 EDT 2022 | mikevb

I'm having a problem with my Mydata My9 pick and place. Basically whenever I try to run the placement calibration program or try to have the machine find fiducials, or basically anything with precision, the machine displays a X MOT motor timeout erro

Loud humming noice from X-Wagon motor

Electronics Forum | Mon Oct 31 02:38:18 EDT 2011 | kenmar

Hi Phil, Thanks I will contact Mydata to see about a possible software upgrade.

my12 motor amplifier channel a error

Electronics Forum | Wed Jan 29 13:01:04 EST 2014 | tech1

Back when the Linear Y wagons first came out Mydata had problem with the original Y amplifier and were swapping out the complete box for customers who had problems. There was also a problem with the encoder that resulted in the same type of errors yo

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 15:33:57 EST 2014 | hans88

Hello Rob, Thanks for your fast reply. I will check the parts you mentioned. You were right about the mot card we swaped it with a new one but that made no difference. Today we tried to find were the problem could be we: - removed the j1, j2 and

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 03:33:42 EST 2014 | hans88

hello people, we have a my12 wich has a problem it gives the following error during hardware initialization: F-MOT-MSETDYN Y/1236 :Motor amplifier channel a error. after this error it says hardware initialization failed. this prevents us of using

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 11:32:52 EST 2014 | rgduval

Hi, Hans, I would have suggested swapping the MOT card out to see if that fixes the issue (or, changing the MOT card with another one to isolate the card), but, it sounds like you've already done that. I'm surprised that MyData would point you towa

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Fri Oct 12 11:21:43 EDT 2018 | tech1

There are 2-X motors and numerous items that could be causing this: 1 of the X motors, 1 of the X transducers, 1 of the couplings connecting the motor and transducer, X Kevlar Belt. If you know how to go into the service portion of the software you

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Thu Oct 11 06:09:50 EDT 2018 | mk15

hello, Does anyone know about the error F-MOT-MOVE X/245 Motor drive inhibited. The machine hardware initiation ready and approximately an hour later, you will see an error. Thanks


mydata motor searches for Companies, Equipment, Machines, Suppliers & Information

best pcb reflow oven

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
Blackfox IPC Training & Certification

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
Online Equipment Auction Jabil Monterrey MX Aug 19, 2024

Software for SMT placement & AOI - Free Download.
Win Source Online Electronic parts

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.