Full Site - : mydata motor (Page 10 of 23)

my12 motor amplifier channel a error

Electronics Forum | Fri Jan 10 11:32:52 EST 2014 | rgduval

Hi, Hans, I would have suggested swapping the MOT card out to see if that fixes the issue (or, changing the MOT card with another one to isolate the card), but, it sounds like you've already done that. I'm surprised that MyData would point you towa

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Fri Oct 12 11:21:43 EDT 2018 | tech1

There are 2-X motors and numerous items that could be causing this: 1 of the X motors, 1 of the X transducers, 1 of the couplings connecting the motor and transducer, X Kevlar Belt. If you know how to go into the service portion of the software you

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Thu Oct 11 06:09:50 EDT 2018 | mk15

hello, Does anyone know about the error F-MOT-MOVE X/245 Motor drive inhibited. The machine hardware initiation ready and approximately an hour later, you will see an error. Thanks

MYDATA My9 Theta error

Electronics Forum | Thu Nov 15 19:56:18 EST 2012 | rgduval

I would have said it sounded like a motor/encoder problem...but, since you found the broken resistor, that was likely the source of your issue. The resistor and capacitor are a filter for the motor, MyData likes to put them on nearly all of the moto

MYDATA TP11 - Motor Controller M error

Electronics Forum | Fri Jun 03 14:21:48 EDT 2011 | rgduval

I haven't seen that particular fail....but... What was the failure with the M controller? Might try moving your MOT cards around, to see if the failure follows one particular card. If so, you'll know you need a new MOT card. That might satisfy th

MYDATA TP11 - Motor Controller M error

Electronics Forum | Fri Jun 03 15:19:19 EDT 2011 | jeremymc

After reseating the M controller boards I was able to get further than I had previously, no save status error, and was given an error about the voltage being wrong. During my last run my company had an electrician in to rewire somethings and put a

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Thu Oct 18 16:09:34 EDT 2018 | emeto

Interesting. What changes in 1 hour? Is there any connection between the error and feeder/magazine change, load reload? Is there any other factor observed in the hour of work that is abnormal?

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Fri Oct 19 08:35:52 EDT 2018 | stephendo

IIRC There is a friction test? If I remember correctly, what is the result?

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Tue Oct 23 11:19:46 EDT 2018 | tech1

This wound up being a power supply cutting out after a period of operation.

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Thu Oct 25 01:13:55 EDT 2018 | mk15

thank you for your advice, the problem was in the elmo source 350V, there was a problem of dropping voltage when the engine accelerated.