Electronics Forum | Sat May 04 11:24:08 EDT 2013 | amelby
Hi, I have been having a problem with my My19E's hydra. The machine comes up with an error "Failed to locate HYDRA tool reference marks" and stops running. It does not happen for about the first two hours of running. It starts to happen after that an
Electronics Forum | Wed May 08 11:20:24 EDT 2013 | amelby
Thanks for the info on the Hydra tubes that will be helpful. I found the answer from one of the Mydata techs. The Camera needs the hydra head to go slower then 1.9m/sec and the setting was at 1.8m/sec. They found out that even if the machine was set
Electronics Forum | Tue May 07 09:20:43 EDT 2013 | dontfeedphils
That may have fixed it, but it doesn't sound like that would be the original cause.
Electronics Forum | Wed May 08 10:40:48 EDT 2013 | huske
We have had this problem before, and Phil was pretty close. On the hydra where the vacuum tubes are connected to the tools shafts you should see a red light inside there. this light locates a lazer cut mark on each of the tool shafts, this lets t
Electronics Forum | Mon May 06 11:24:04 EDT 2013 | amelby
Hi, Thanks for the help, The software on the Mydata is at least 2.9 I just had it upgraded last year. Arnie
Electronics Forum | Mon May 06 11:16:07 EDT 2013 | rdubya
if you don't have anything obstructing the camera then it sounds like it could be the camera power supply going bad. what version of tpsys are you running?
Electronics Forum | Thu Feb 01 14:57:05 EST 2024 | cflames17
Have you tried reinstalling all the tools? This appears to be a problem with the tool bank being out of tolerance. Reinstall each tool in your tool bank one by one. Are the hydra tools ok?
Electronics Forum | Sat Oct 03 07:26:01 EDT 2009 | cflames17
Check the reference plate on the hydra to make sure it is not cracked or delaminated. I have had problems with the glue coming loose and the plate flapping causing this same problem. check hydra camera calibrations, this to may help.
Electronics Forum | Tue Mar 04 17:17:29 EST 2014 | catsem23
Hi I'm trying to pick and place a lot of sod523 components with a mydata my12. I'm using C14 standard tool and Hydra tool H01. For some reason no matter what I try to do when the head picks the component with the C14 tool the machine emergency stops